Wyo. Code R. 020-0002-3
Air Quality
Effective Date: 12/27/2024 to Current
Rule Type: Current Rules & Regulations
Reference Number: 020.0002.3.12272024
General Emission Standards
(a) This Chapter establishes limits on the quantity, rate, or concentration of emissions of air pollutants, including any requirements which limit the level of opacity, prescribe equipment, set fuel specifications, or prescribe operation or maintenance procedures. These general emission standards may be superseded by specific emission standards required in other chapters of the Wyoming Air Quality Standards and Regulations (WAQSR). Section 9 incorporates by reference all Code of Federal Regulations (CFRs), including their Appendices, cited in this Chapter and all American Society for Testing and Materials (ASTM) standards cited in this chapter.
(a) Visible emissions of any contaminant discharged into the atmosphere from any single new source of emission whatsoever as determined by a qualified observer shall be limited to 20 percent opacity;
Provided, that:
(i) An owner or operator of an affected facility of the type described in Chapter 3, Section 2(h)(i) that has a heat input of not less than 2500 x 10⁶ Btu per hour, may request the Wyoming Department of Environmental Quality, Air Quality Division Administrator (Administrator) to determine opacity of emissions from such affected facility during initial performance tests required by Chapter 3, Section 2(i) or during other performance tests thereafter.
(ii) Upon receipt from such owner or operator of the written report of the results of the performance tests required by WAQSR Chapter 6, Section 2(i) or later performance tests, the Administrator will make a finding concerning compliance with opacity and other applicable standards. If the Administrator finds that the affected facility is in compliance with all applicable standards for which performance tests are conducted but fails to meet an applicable opacity standard, he shall notify the owner or operator and advise him that he may petition the Administrator within ten days of receipt of notification to make appropriate adjustment to the opacity standard for such affected facility.
(iii) The Administrator will grant a petition upon a satisfactory demonstration by the owner or operator that the affected facility and associated air pollution control equipment was operated and maintained in a manner to minimize the opacity of emissions during the performance tests; that the performance tests were performed under the conditions prescribed by the Administrator; and that the affected facility and associated air pollution control equipment were incapable of being adjusted or operated to meet the applicable opacity standard at or near the facility's designed capacity.
(iv) The Administrator will establish an opacity standard for such affected facility meeting the above requirements at a level at which the source will be able, as indicated by the performance and opacity tests, to meet the opacity standard at all times during which the source is meeting the mass or concentration emission standard and during which the facility and air pollution equipment is being operated properly and maintained to minimize the opacity of emissions and mass emission rate.
(b) Visible emissions of any contaminant discharged into the atmosphere from any single existing source of emission whatsoever as determined by a qualified observer shall be limited to 40 percent opacity. This limitation shall not apply to existing incinerators or wood waste burners.
(c) The emissions of visible air pollutants from gasoline engines shall be eliminated except for periods not exceeding five consecutive seconds.
(d) The emissions of visible air pollutants from stationary or portable diesel engines as determined by a qualified observer shall be limited to 30 percent opacity below 7500 feet elevation except for periods not exceeding ten consecutive seconds.
(e) Unless restricted by more stringent emission limits established elsewhere in the WAQSR or permit conditions, any single source may discharge for a period or periods aggregating not more than 6 minutes in any hour contaminants;
(i) Having an equivalent opacity of not more than 40 percent as determined by a qualified observer.
(f) Fugitive Dust. Sources operating within the State of Wyoming are required to control fugitive dust emissions. The following control measures or any equivalent method approved by the Administrator shall be considered appropriate for minimizing fugitive dust:
(i) Construction/Demolition Activities.
(A) Any person engaged in clearing or leveling of land, earthmoving, excavation, or movement of trucks or construction equipment over access haul roads or cleared land shall take steps to minimize fugitive dust from those activities. Such control measures may include frequent watering and/or chemical stabilization.
(B) Any person engaged in demolition activities including razing of homes, buildings, or other structures; or removing paving material from roads and/or parking areas shall take steps to minimize fugitive dust from such activities. Such control measures may include frequent watering and/or chemical stabilization.
(C) Any person who is engaged in construction or demolition activities which tracks earth or other materials onto paved streets shall promptly remove such material by water or other means.
(D) Any person engaged in sandblasting or similar operations shall take steps to minimize fugitive dust from such activities. Such control measures may include the installation and use of hoods, fans and fabric filters to enclose and vent the handling of dusty materials.
(ii) Handling and Transporting of Materials.
(A) Any person owning, operating or maintaining a new or existing material storage, handling and/or hauling operation shall minimize fugitive dust from such an operation. Control measures may include the application of asphalt, oil, water or suitable chemicals on unpaved roads, material stockpiles and other surfaces which can give rise to airborne dusts. Control measures for material handling may also include installation and use of hoods, fans and fabric filters to enclose and vent dusty materials.
(B) When transporting materials likely to give rise to airborne dust, open bodied trucks shall be covered when in motion.
(iii) Agricultural Practices.
(A) Any person engaged in agricultural practices, such as tilling of land and application of fertilizers shall operate in a manner to minimize fugitive dust emissions.
(g) The emission of particulate matter from any new source shall be limited as indicated in Table I. The emission of particulate matter from any existing source shall be limited as indicated in Table II.
(i) Process weight per hour means the total weight of all materials introduced into any specific process that may cause any emissions of particulate matter, including solid fuels, but excluding liquids or gases and used solely as fuels, and excluding air introduced for purposes of combustion, and excluding the weight of any water, water vapor or steam that may be introduced as part of the total materials. However, water contained as part of the normal input to a beet pulp dryer process shall be included as part of the process weight per hour. The process weight rate per hour referred to in this section shall be based upon the maximum design production rate of the equipment unless otherwise restricted by enforceable limits on potential to emit.
(ii) For a cyclical or batch operation, the process weight per hour is derived by dividing the total process weight by the number of hours in one complete operation from the beginning of any given process to the completion thereof, excluding any time during which the equipment is idle.
(iii) For a continuous operation, the process weight per hour is derived by dividing the process weight for a typical period of time.
(iv) Emission tests related to this regulation shall be measured in accordance with the requirements of Chapter 3, Section 2(h)(iv).
| TABLE I | |
|---|---|
| PROCESS WEIGHT RATE (lbs/hr) | EMISSION RATE (lbs/hr) |
| 50 | 0.36 |
| 100 | 0.55 |
| 500 | 1.53 |
| 1,000 | 2.25 |
| 5,000 | 6.34 |
| 10,000 | 9.73 |
| 20,000 | 14.99 |
| 60,000 | 29.60 |
| 80,000 | 31.19 |
| 120,000 | 33.28 |
| 160,000 | 34.85 |
| 200,000 | 36.11 |
| 400,000 | 40.35 |
| 1,000,000 | 46.72 |
Interpolation of the data in Table I for the process weight rates up to 60,000 lbs/hr shall be accomplished by the use of the equation:
$$E = 3.59 P0.62 \quad P \leq 30 \text{ tons/hr}$$
and interpolation and extrapolation of the data for process weight rates in excess of 60,000 lbs/hr shall be accomplished by use of the equation:
$$E = 17.31 P0.16 \quad P > 30 \text{ tons/hr}$$
Where: E = Emissions in pounds per hour. P = Process weight rate in tons per hour.
| TABLE II | |||||
|---|---|---|---|---|---|
| PROCESS WEIGHT RATE | RATE OF EMISSION | PROCESS WEIGHT RATE | RATE OF EMISSION | ||
| lb/hr | tons/hr | lb/hr | lb/hr | tons/hr | lb/hr |
| 100 | 0.05 | 0.551 | 16,000 | 8 | 16.5 |
| 200 | 0.10 | 0.877 | 18,000 | 9 | 17.9 |
| 400 | 0.20 | 1.40 | 20,000 | 10 | 19.2 |
| 600 | 0.30 | 1.83 | 30,000 | 15 | 25.2 |
| 800 | 0.40 | 2.22 | 40,000 | 20 | 30.5 |
| 1,000 | 0.50 | 2.58 | 50,000 | 25 | 35.4 |
| 1,500 | 0.75 | 3.38 | 60,000 | 30 | 40.0 |
|---|---|---|---|---|---|
| 2,000 | 1.00 | 4.10 | 70,000 | 35 | 41.3 |
| 2,500 | 1.25 | 4.76 | 80,000 | 40 | 42.5 |
| 3,000 | 1.50 | 5.38 | 90,000 | 45 | 43.6 |
| 3,500 | 1.75 | 5.96 | 100,000 | 50 | 44.6 |
| 4,000 | 2.00 | 6.52 | 120,000 | 60 | 46.3 |
| 5,000 | 2.50 | 7.58 | 140,000 | 70 | 47.8 |
| 6,000 | 3.00 | 8.56 | 160,000 | 80 | 49.0 |
| 7,000 | 3.50 | 9.49 | 200,000 | 100 | 51.2 |
| 8,000 | 4.00 | 10.4 | 1,000,000 | 500 | 69.0 |
| 9,000 | 4.50 | 11.2 | 2,000,000 | 1,000 | 77.6 |
| 10,000 | 5.00 | 12.0 | 6,000,000 | 3,000 | 92.7 |
| 12,000 | 6.00 | 13.6 |
Interpolation of the data in Table II for process weight rates up to 60,000 lb/hr shall be accomplished by use of the equation $E = 4.10 P0.67$, and interpolation and extrapolation of the data for process weight rates in excess of 60,000 lb/hr shall be accomplished by use of the equation:
$$E = 55.0 P0.11 - 40, \text{ where } E = \text{rate of emission in lb/hr}$$
$$\text{and } P = \text{process weight rate in tons/hr}$$
Notwithstanding any other provision of Table II, any existing air contaminant source utilizing an air pollution control device having a collection efficiency of 99.5 percent or better, shall be deemed to be in compliance with all provisions of this regulation. Such efficiency shall be determined by a professional engineer licensed to practice in Wyoming and all expenses incurred in such determination shall be defrayed by the person responsible for the emission.
(h) The emissions of particulate matter from existing sources where fuel burning equipment is used for indirect heating shall be limited as shown in Figure 1 and shall be applicable to equipment burning solid fuel.
FIGURE 1 PARTICULATE EMISSION LIMITS
The emissions of particulate matter from new sources where fuel burning equipment is used for indirect heating shall be limited to 0.10 pound per million Btu input (0.18 grams per million calories) maximum 2-hour average. Except to the extent that an opacity standard has been established for an affected facility pursuant to Chapter 3, Section 2(a)(i) through (iv) hereof, the visible emissions of particulate matter from new sources where fuel burning equipment is used for indirect heating shall be no greater than 20 percent opacity, except that 40 percent opacity shall be permitted for not more than 2 minutes in any hour. This regulation is not applicable to residential or commercial fuel burning equipment with a heat input of less than 10 x 10⁶ Btu/hr and used exclusively to produce building heat.
(i) This regulation applies to installations in which fuel is burned for the primary purpose of producing steam, hot water, or hot air or other indirect heating of liquids, gases, or solids, and, in the course of doing so, the products of combustion do not come into direct contact with process materials. Fuels include those such as coal, coke, lignite, fuel oil, and wood, but do not include refuse. When any products or byproducts of a manufacturing process are burned for the same purpose or in conjunction with any fuel, the same maximum emission limitations shall apply.
(ii) For purposes of this regulation, the heat input shall be the aggregate heat content of all fuels whose products of combustion pass through a stack or stacks, or the heat input value used shall be the equipment manufacturer or designer's guaranteed maximum input, whichever is greater. The total heat input of all fuel burning units at a plant or on a premise shall be used for determining the maximum allowable amount of particulate matter which may be emitted.
(iii) The amount of particulate matter emitted shall be measured by test Methods 1 through 5, Appendix A, 40 CFR part 60. The Administrator may require that variations to said methods be included or that entirely different methods be utilized if he determines that such variations or different methods are necessary in order for the test data to reflect the actual emission rate of particulate matter.
(i) The emission of particulate matter from any incinerator shall be limited to:
(i) 0.20 pound per 100 pounds (2 grams per kilogram) of refuse charged as determined by a source test method approved by the Administrator for stationary sources as described in Section 2(h)(ii) of this chapter; and
(ii) A shade or density equal to but not greater than 20 percent opacity as determined by a qualified observer.
(a) The emission standards for nitrogen oxides, measured in accordance with Method 7 of 40 CFR Part 60, Appendix A-4, or by an equivalent method are:
(i) The emission of nitrogen oxides from new gas fired fuel burning equipment calculated as nitrogen dioxide shall be limited to 0.20 pound per million Btu (0.36 grams per million gram calories) of heat input.
(ii) The emission of nitrogen oxides from existing gas fired fuel burning equipment calculated as nitrogen dioxide shall be limited to 0.23 pound per million Btu (0.41 grams per million gram calories) of heat input.
(iii) The emission of nitrogen oxides from new oil fired fuel burning equipment calculated as nitrogen dioxide shall be limited to 0.30 pounds per million Btu (0.54 grams per million gram calories) of heat input for units having a heat input of 1.0 million Btu per hour (250 million gram calories/hour) or greater and 0.60 pounds per million Btu (1.08 grams per million gram calories) of heat input for units having a heat input less than 1.0 million Btu per hour (250 million gram calories/hour).
(iv) The emission of nitrogen oxides from existing oil fired fuel burning equipment calculated as nitrogen dioxide shall be limited to 0.46 pound per million Btu (0.83 grams per million gram calories) of heat input for units having a heat input of 250 million Btu per hour (62.5 billion gram calories/hour) or greater and 0.60 pound per million Btu (1.08 grams per million gram calories) of heat input for units having a heat input less than 250 million Btu per hour (62.5 billion gram calories/hour).
(v) The emission of nitrogen oxides from new nitric acid manufacturing plants, calculated as nitrogen dioxide shall be limited to 3 pounds per ton (1.5 kilograms per metric ton) of acid produced, maximum 2-hour average.
(vi) The emission of nitrogen oxides from new solid fossil fuel (except lignite) fired fuel burning equipment calculated as nitrogen dioxide shall be limited to 0.70 pounds per million Btu (1.26 grams per million gram calories) heat input.
(vii) The emission of nitrogen oxides from existing solid fossil fuel (except lignite) fired fuel burning equipment calculated as nitrogen dioxide shall be limited to 0.75 pounds per million Btu (1.35 grams per million gram calories) heat input.
(a) The emission of carbon monoxide in stack gases from any stationary source shall be limited as may be necessary to prevent ambient standards described in WAQSR Chapter 2, Section 5 from being exceeded. Measures considered appropriate for such control are:
(i) Treatment of the waste gas stream by installation and use of a direct flame afterburner or other means which will achieve the required reduction as approved by the Administrator.
(a) The term “volatile organic compounds” (VOCs) is defined in 40 CFR Part 51.100(s), 51.100(s)(1), and 51.100(s)(5), incorporated by reference under Section 9(a) of this chapter.
(b) VOC emissions shall be limited through the application of Best Available Control Technology (BACT) in accordance with Chapter 6, Section 2 of these regulations. Notwithstanding the above, whenever acceptable control of VOC emissions from vapor blowdown, emergency relief systems, or VOC emissions generated from oil and gas production, storage, exploration, development, or processing operations is specified pursuant to these regulations as a flare, the flare shall not exceed a 20 percent opacity emission standard. If acceptable control of VOC emissions is specified as a smokeless flare, the definition given in subsection (i) of this section applies.
(i) For the purposes of this section, “smokeless flare” means a flare designed for and operated with no visible emissions except for periods not to exceed a total of 5 minutes during any 2 consecutive hours.
(ii) Each flare subject to Chapter 3, Section 6(b) must be equipped and operated with an automatic igniter or a continuous burning pilot which must be maintained in good working order.
(a) Any exit process gas stream containing hydrogen sulfide which is discharged to the atmosphere from any source shall be vented, incinerated, flared or otherwise disposed of in such a manner that ambient sulfur dioxide and hydrogen sulfide standards described in Chapter 2, Sections 4 and 7 are not exceeded.
(a) Applicability. The provisions of this section are applicable to those sources specified in paragraphs (g) through (n), (q), and (r).
(b) Definitions. All terms that are used in this section and are not defined below are given the same meaning as in Chapter 1, Section 3 of these regulations.
“Active waste disposal site” means any disposal site other than an inactive site.
“Adequately wet” means sufficiently mix or penetrate with liquid to prevent the release of particulates. If visible emissions are observed coming from asbestos-containing material, then that material has not been adequately wetted. However, the absence of visible emissions is not sufficient evidence of being adequately wet.
“Asbestos” means the asbestiform varieties of serpentinite (chrysotile), riebeckite (crocidolite), cummingtonite-grunerite, anthophyllite, and actinolite-tremolite.
“Asbestos-containing waste materials” means mill tailings or any waste that contains commercial asbestos and is generated by a source subject to the provisions of this section. This term includes filters from control devices, friable asbestos waste material, and bags or other similar packaging contaminated with commercial asbestos. As applied to demolition and renovation operations, this term also includes regulated asbestos-containing material waste and materials contaminated with asbestos including disposable equipment and clothing.
“Asbestos tailings” means any solid waste that contains asbestos and is a product of asbestos mining or milling operations.
“Asbestos waste from control devices” means any waste material that contains asbestos and is collected by a pollution control device.
“Category I nonfriable asbestos-containing material (ACM)” means asbestos-containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than 1 percent asbestos as determined using the method specified in 40 CFR Part 763 Appendix E, Section 1, Polarized Light Microscopy.
“Category II nonfriable ACM” means any material, excluding Category I nonfriable ACM, containing more than 1 percent asbestos as determined using the methods specified in 40 CFR Part 763 Appendix E, Section 1, Polarized Light Microscopy, that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
“Commercial asbestos” means any material containing asbestos that is extracted from ore and has value because of its asbestos content.
“Cutting” means to penetrate with a sharp-edged instrument and includes sawing, but does not include shearing, slicing, or punching.
“Demolition” means the wrecking or taking out of any load-supporting structural member of a facility together with any related handling operations or the intentional burning of any facility.
“Emergency renovation operation” means a renovation operation that was not planned but results from a sudden, unexpected event that, if not immediately attended to, presents a safety or public health hazard, is necessary to protect equipment from damage, or is necessary to avoid imposing an unreasonable financial burden. This term includes operations necessitated by nonroutine failures of equipment.
“Fabricating” means any processing (e.g., cutting, sawing, drilling) of a manufactured product that contains commercial asbestos, with the exception of processing at temporary sites (field fabricating) for the construction or restoration of facilities. In the case of friction products, fabricating includes bonding, debonding, grinding, sawing, drilling, or other similar operations performed as part of fabricating.
“Facility” means any institutional, commercial, public, industrial, or residential structure, installation, or building (including any structure, installation, or building containing condominiums or individual dwelling units operated as a residential cooperative, but excluding residential buildings having four or fewer dwelling units); any ship; and any active or inactive waste disposal site. For the purposes of this definition, any building, structure, or installation that contains a loft used as a dwelling is not considered a residential structure, installation, or building. Any structure, installation or building that was previously subject to this section is not excluded, regardless of its current use or function.
“Facility component” means any part of a facility including equipment.
“Friable asbestos material” means any material containing more than 1 percent asbestos as determined using the method specified in 40 CFR Part 763 Appendix E, Section 1, Polarized Light Microscopy, that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. If the asbestos content is less than 10 percent as determined by a method other than point counting by polarized light microscopy (PLM), verify the asbestos content by point counting using PLM.
“Fugitive source” means any source of emissions not controlled by an air pollution control device.
“Glove bag” means a sealed compartment with attached inner gloves used for the handling of asbestos-containing materials. Properly installed and used, glove bags provide a small work area enclosure typically used for small-scale asbestos stripping operations. Information on glove-bag installation, equipment and supplies, and work practices is contained in the Occupational Safety and Health Administration’s (OSHA’s) final rule on occupational exposure to asbestos (29 CFR § 1926.1101(g)(5)(ii)).
“Grinding” means to reduce to powder or small fragments and includes mechanical chipping or drilling.
“In poor condition” means the binding of the material is losing its integrity as indicated by peeling, cracking, or crumbling of the material.
“Inactive waste disposal site” means any disposal site or portion of it where additional asbestos-containing waste material has not been deposited within the past year.
“Installation” means any building or structure or any group of buildings or structures at a single demolition or renovation site that are under the control of the same owner or operator (or owner or operator under common control).
“Leak-tight” means that solids or liquids cannot escape or spill out. It also means dust-tight.
“Malfunction” means any sudden and unavoidable failure of air pollution control equipment or process equipment or of a process to operate in a normal or usual manner so that emissions of asbestos are increased. Failures of equipment shall not be considered malfunctions if they are caused in any way by poor maintenance, careless operation, or any other preventable upset conditions, equipment breakdown, or process failure.
“Manufacturing” means the combining of commercial asbestos--or, in the case of woven friction products, the combining of textiles containing commercial asbestos--with any other material(s), including commercial asbestos, and the processing of this combination into a product. Chlorine production is considered a part of manufacturing.
“Natural barrier” means a natural object that effectively precludes or deters access. Natural barriers include physical obstacles such as cliffs, lakes or other large bodies of water, deep and wide ravines, and mountains. Remoteness by itself is not a natural barrier.
“Nonfriable asbestos-containing material” means any material containing more than 1 percent asbestos as determined using the method specified in 40 CFR Part 763 Appendix E, Section 1, Polarized Light Microscopy, that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
“Nonscheduled renovation operation” means a renovation operation necessitated by the routine failure of equipment, which is expected to occur within a given period based on past operating experience, but for which an exact date cannot be predicted.
“Outside air” means the air outside buildings and structures, including, but not limited to, the air under a bridge or in an open air ferry dock.
“Owner or operator of a demolition or renovation activity” means any person who owns, leases, operates, controls, or supervises the facility being demolished or renovated or any person who owns, leases, operates, controls, or supervises the demolition or renovation operation, or both.
“Particulate asbestos material” means finely divided particles of asbestos or material containing asbestos.
“Planned renovation operations” means a renovation operation, or a number of such operations, in which some regulated asbestos-containing material (RACM) will be removed or stripped within a given period of time and that can be predicted. Individual nonscheduled operations are included if a number of such operations can be predicted to occur during a given period of time based on operating experience.
“Regulated asbestos-containing material (RACM)” means: (a) Friable asbestos material, (b) Category I nonfriable ACM that has become friable, (c) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this chapter.
“Remove” means to take out RACM or facility components that contain or are covered with RACM from any facility.
“Renovation” means altering a facility or one or more facility components in any way, including the stripping or removal of RACM from a facility component. Operations in which load-supporting structural members are wrecked or taken out are demolitions.
“Resilient floor covering” means asbestos-containing floor tile, including asphalt and vinyl floor tile, and sheet vinyl floor covering containing more than 1 percent asbestos as determined using polarized light microscopy according to the method specified in 40 CFR Part 763 Appendix E, Section 1, Polarized Light Microscopy.
“Strip” means to take off RACM from any part of a facility or facility components.
“Structural member” means any load supporting member of a facility, such as beams and load supporting walls; or any nonload-supporting member, such as ceilings and nonload-supporting walls.
“Visible emissions” means any emissions, which are visually detectable without the aid of instruments, coming from RACM or asbestos-containing waste material, or from any asbestos milling, manufacturing, or fabricating operation. This does not include condensed, uncombined water vapor.
“Waste generator” means any owner or operator of a source covered by this section whose act or process produces asbestos-containing waste material.
“Waste shipment record” means the shipping document, required to be originated and signed by the waste generator, used to track and substantiate the disposal of asbestos-containing waste material.
“Working day” means Monday through Friday and includes holidays that fall on any of the days Monday through Friday.
(c) Units and Abbreviations: Used in this section are abbreviations and symbols of units of measure. These are defined as follows:
(i) System International (SI) Units of Measure:
g = gram kg = kilogram m = meter m2 = square meter m3 = cubic meter
(ii) Other Units of Measure:
C = Celsius (centigrade) F = Fahrenheit ft2 = square feet ft3 = cubic feet yd2 = square yards min = minute oz = ounces
(d) Address: All requests, reports, applications, submittals, and other communications to the Administrator pursuant to this section shall be submitted to the following address:
(i) Wyoming Department of Environmental Quality, Air Quality Division, 200 West 17th St., Cheyenne, Wyoming 82002.
(e) [Reserved]
(f) Circumvention: No owner or operator shall build, erect, install, or use any article, machine, equipment, process, or method, the use of which conceals an emission which would otherwise constitute a violation of an applicable standard. Such concealment includes, but is not limited to, the use of gaseous dilutants to achieve compliance with a visible emissions standard, and the piecemeal carrying out of an operation to avoid coverage by a standard that applies only to operations larger than a specified size.
(g) Standard for Waste Disposal for Non-Facility Owners and Operators.
(i) All owners and operators conducting an asbestos abatement project, including an abatement project on a residential building, shall be responsible for complying with
Federal requirements and State standards for packaging, transportation, and delivery to an approved waste disposal facility as provided in paragraph (m) of this section. A non-facility is any other facility not defined under the definition of “facility” including residential buildings having four or fewer dwelling units.
(h) Standard for Manufacturing.
(i) Applicability. This paragraph applies to the following manufacturing operations using commercial asbestos.
(A) The manufacture of cloth, cord, wicks, tubing, tape, twine, rope, thread, yarn, roving, lap, or other textile materials.
(B) The manufacture of cement products.
(C) The manufacture of fireproofing and insulating materials.
(D) The manufacture of friction products.
(E) The manufacture of paper, millboard, and felt.
(F) The manufacture of floor tile.
(G) The manufacture of paints, coatings, caulks, adhesives, and sealants.
(H) The manufacture of plastics and rubber materials.
(I) The manufacture of chlorine utilizing asbestos diaphragm technology.
(J) The manufacture of shotgun shell wads.
(K) The manufacture of asphalt concrete.
(ii) Standard. Each owner or operator of any of the manufacturing operations to which this paragraph applies shall either:
(A) Discharge no visible emissions to the outside air from these operations or from any building or structure in which they are conducted or from any fugitive sources; or
(B) Use the methods specified by paragraph (o) of this section to clean emissions containing asbestos material from these operations before they escape to, or are vented to, the outside air.
(C) Monitor each potential source of asbestos emissions from any part of the manufacturing facility, including air cleaning devices, process equipment, and buildings housing material processing and handling equipment, at least once each day during daylight hours for visible emissions to the outside air during periods of operation. The monitoring shall be by the visual observation of at least 15 seconds duration per source of emissions.
(D) Inspect each air cleaning device at least once each week for proper operation and for changes that signal potential for malfunctions, including, to the maximum extent possible without dismantling other than opening the device, the presence of tears, holes, and abrasions in filter bags and for dust deposits on the clean side of bags. For air cleaning devices that cannot be inspected on a weekly basis according to this paragraph, submit to the Administrator, and revise as necessary, a written maintenance plan to include, at a minimum, the following:
(I) Maintenance schedule.
(II) Recordkeeping plan.
(E) Maintain records of the results of visible emission monitoring and air cleaning device inspections using a format similar to that shown in Figures 1 and 2 and include the following:
(I) Date and time of each inspection.
(II) Presence or absence of visible emissions.
(III) Condition of fabric filters, including presence of any tears, holes and abrasions.
Figure 1. Record of Visible Emission Monitoring
| Date of Inspection (MM/DD/YY) | Time of Inspection (a.m./p.m.) | Control Device or fugitive emission source designation or number | Visible Emissions Observed (yes/no) Corrective Action taken | Daily Operating Hours | Inspector's Initials |
|---|---|---|---|---|---|
Figure 2. Air Pollution Control Device Inspection Checklist
| 1. Control Device Designation or Number: _____ | |||
|---|---|---|---|
| 2. Date of Inspection: _ __ _____ | |||
| 3. Time of Inspection: _ __ _____ | |||
| 4. Is Control Device Operating Properly (yes or no) _ __ _____ | |||
| 5. Abrasions in bags (yes or no) _ __ _____ | |||
| 6. Dust on Clean Side of bags (yes or no) _ __ _____ | |||
| 7. Other Signs of Malfunctions or Potential Malfunctions (yes or no) _ __ _____ | |||
| 8. Describe Other Malfunctions or Signs of Potential Malfunctions: | |||
| _____ | |||
| 9. Describe Corrective Action(s) Taken: | |||
| _____ | |||
| 10. Date and Time Corrective Action Taken: _ __ _____ | |||
| 11. Inspected By: | |||
| (Print/Type Name) | (Title) | (Signature) | (Date) |
| (Print/Type Name) | (Title) | (Signature) | (Date) |
(IV) Presence of dust deposits on clean side of fabric filters. (V) Brief description of corrective actions taken, including date and time.
(VI) Daily hours of operation for each air cleaning device.
(F) Furnish upon request, and make available at the affected facility during normal business hours for inspection by the Administrator, all records required under this paragraph.
(G) Retain a copy of all monitoring and inspection records for at least 2 years.
(H) Submit quarterly a copy of the visible emission monitoring records to the Administrator if visible emissions occurred during the report period. Quarterly reports shall be postmarked by the 30th day following the end of the calendar quarter.
(i) Standard for Demolition and Renovation.
(i) Applicability. To determine which requirements of paragraphs (i)(i), (i)(ii), and (i)(iii) apply to the owner or operator of a demolition or renovation activity and prior to the commencement of the demolition or renovation, thoroughly inspect the affected facility or part of the facility where the demolition or renovation operation will occur for the presence of asbestos, including Category I and Category II nonfriable ACM. The requirements of paragraphs (i)(ii) and (i)(iii) apply to each owner or operator of a demolition or renovation activity, including the removal of RACM as follows:
(A) In a facility being demolished, all the requirements of paragraphs (i)(ii) and (i)(iii) apply, except as provided in paragraph (i)(i)(C), if the combined amount of RACM is:
(I) At least 80 linear meters (260 linear feet) on pipes or at least 15 square meters (160 square feet) on other facility components, or
(II) At least 1 cubic meter (35 cubic feet) off facility components where the length or area could not be measured previously.
(B) In a facility being demolished, only the notification requirements of paragraphs (i)(ii)(A), (B), (C)(I) and (IV), and (D)(I) through (D)(IX) and (XVI) apply, if the combined amount of RACM is:
(I) Less than 80 linear meters (260 linear feet) on pipes and less than 15 square meters (160 square feet) on other facility components, and
(II) Less than one cubic meter (35 cubic feet) off facility components where the length or area could not be measured previously or there is no asbestos.
(C) If the facility is being demolished under an order of a State or local government agency, issued because the facility is structurally unsound and in danger of imminent collapse, only the requirements of paragraphs (i)(ii)(A), (i)(ii)(B), (i)(ii)(C)(III), (i)(ii)(D) (except (i)(ii)(D)(VIII)), (i)(ii)(E), and (i)(iii)(D) through (i)(iii)(I) apply.
(D) In a facility being renovated, including any individual nonscheduled renovation operation, all the requirements of paragraphs (i)(ii) and (i)(iii) apply if the combined amount of RACM to be stripped, removed, dislodged, cut, drilled, or similarly disturbed is:
(I) At least 80 linear meters (260 linear feet) on pipe or at least 15 square meters (160 square feet) on other facility components, or
(II) At least 1 cubic meter (35 cubic feet) off facility components where the length or area could not be measured previously.
(III) To determine whether paragraph (i)(i)(D) applies to planned renovation operations involving individual nonscheduled operations, predict the combined additive amount of RACM to be removed or stripped during a calendar year or January 1 through December 31.
(IV) To determine whether paragraph (i)(i)(D) applies to emergency renovation operations, estimate the combined amount of RACM to be removed or stripped as a result of the sudden, unexpected event that necessitated the renovation.
(E) In a facility being renovated, only the notification requirements of paragraphs (i)(ii)(A), (B), (C)(I) and (IV), and (D)(I) through (IX) and (XVI) apply, if the combined amount of RACM is:
(I) Less than 80 linear meters (260 linear feet) on pipes or less than 15 square meters (160 square feet) on other facility components, and
(II) Less than 1 cubic meter (35 cubic feet) off facility components where the length or area could not be measured previously or there is no asbestos.
(ii) Notification Requirements. Each owner or operator of a demolition or renovation activity to which this section applies shall:
(A) Provide the Administrator with written notice of intention to demolish or renovate. Delivery of the notice by U.S. Postal Service, commercial delivery service, or hand delivery is acceptable.
(B) Update notice, as necessary, including when the amount of asbestos affected changes by at least 20 percent.
(C) Postmark or deliver the notice as follows:
(I) At least 10 working days before asbestos stripping or removal work or any other activity begins (such as site preparation that would break up, dislodge or similarly disturb asbestos material), if the operation is described in paragraphs (i)(i)(A) and (D) (except (i)(i)(D)(III) and (i)(i)(D)(IV)). If the operation is as described in paragraph (i)(i)(B), notification is required 10 working days before demolition begins.
(II) At least 10 working days before the end of the calendar year preceding the year for which notice is being given for renovations described in paragraph (i)(i)(D)(III).
(III) As early as possible before, but not later than, the following working day if the operation is a demolition ordered according to paragraph (i)(i)(C) or, if the operation is a renovation described in paragraph (i)(i)(D)(IV).
(IV) For asbestos stripping or removal work in a demolition or renovation operation, described in paragraphs (i)(i)(A) and (D) (except (i)(i)(D)(III) and (i)(i)(D)(IV)), and for a demolition described in paragraph (i)(i)(B), that will begin on a date other than the one contained in the original notice, notice of the new start date must be provided to the Administrator as follows:
(1.) When the asbestos stripping or removal operation or demolition operation covered by this paragraph will begin after the date contained in the notice,
a. Notify the Administrator of the new start date by telephone as soon as possible before the original start date, and
b. Provide the Administrator with a written notice of the new start date as soon as possible before, and no later than, the original start date. Delivery of the updated notice by the U.S. Postal Service, commercial delivery service, or hand delivery is acceptable.
(2.) When the asbestos stripping or removal operation or demolition operation covered by this paragraph will begin on a date earlier than the original start date,
a. Provide the Administrator with a written notice of the new start date at least 10 working days before asbestos stripping or removal work begins.
b. For demolitions covered by paragraph (i)(i)(B), provide the Administrator written notice of a new start date at least 10 working days before commencement of demolition. Delivery of updated notice by U.S. Postal Service, commercial delivery service, or hand delivery is acceptable.
(3.) In no event shall an operation covered by this paragraph begin on a date other than the date contained in the written notice of the new start date.
(D) Include the following in the notice:
(I) An indication of whether the notice is the original or a revised notification.
(II) Name, address, and telephone number of both the facility owner and operator and the asbestos removal contractor owner or operator.
(III) Type of operation: demolition or renovation.
(IV) Description of the facility or affected part of the facility including the size (square meters [square feet] and number of floors), age, and present and prior use of the facility.
(V) Procedure, including analytical methods, employed to detect the presence of RACM and Category I and Category II nonfriable ACM.
(VI) Estimate of the approximate amount of RACM to be removed from the facility in terms of length of pipe in linear meters (linear feet), surface area in square meters (square feet) on other facility components, or volume in cubic meters (cubic feet) if off the facility components. Also estimate the approximate amount of Category I and Category II nonfriable ACM in the affected part of the facility that will not be removed before demolition.
(VII) Location and street address (including building number or name and floor or room number, if appropriate), city, county, and state, or the facility being demolished or renovated.
(VIII) Scheduled starting and completion dates of asbestos removal work (or any other activity, such as site preparation that would break up, dislodge, or similarly disturb asbestos material) in a demolition or renovation; planned renovation operations involving individual nonscheduled operations shall only include the beginning and ending dates of the report period as described in paragraph (i)(i)(D)(III).
(IX) Scheduled starting and completion dates of demolition or renovation.
(X) Description of planned demolition or renovation work to be performed and method(s) to be employed, including demolition or renovation techniques to be used and description of affected facility components.
(XI) Description of work practices and engineering controls to be used to comply with the requirements of this section, including asbestos removal and waste-handling emission control procedures.
(XII) Name and location of the waste disposal site where the asbestos-containing waste material will be deposited.
(XIII) A certification that the individuals supervising and performing the stripping and removal described by this notification have received the training required by paragraph (i)(iii)(H).
(XIV) For facilities described in paragraph (i)(i)(C), the name, title, and authority of the State or local government representative who has ordered the demolition, the date that the order was issued, and the date on which the demolition was ordered to begin. A copy of the order shall be attached to the notification.
(XV) For emergency renovations described in paragraph (b)(xii) of this section, the date and hour that the emergency occurred, a description of the sudden, unexpected event, and an explanation of how the event caused an unsafe condition, or would cause equipment damage or an unreasonable financial burden.
(XVI) Description of procedures to be followed in the event that unexpected RACM is found or Category II nonfriable ACM becomes crumbled, pulverized, or reduced to powder.
(XVII) Name, address, and telephone number of the waste transporter.
(E) The information required in paragraph (i)(ii)(D) must be reported using a form similar to that shown in Figure 3.
(iii) Procedures for Asbestos Emission Control. Each owner or operator of a demolition or renovation activity to whom this paragraph applies, according to paragraph (i)(i), shall comply with the following procedures:
(A) Remove all RACM from a facility being demolished or renovated before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access to the material for subsequent removal. RACM need not be removed before demolition if:
(I) It is Category I nonfriable ACM that is not in poor condition and is not friable.
(II) It is on a facility component that is encased in concrete or other similarly hard material and is adequately wet whenever exposed during demolition; or (III) It was not accessible for testing and was, therefore, not discovered until after demolition began and, as a result of the demolition, the material cannot be safely removed. If not removed for safety reasons, the exposed RACM and any asbestos-contaminated debris must be treated as asbestos-containing waste material and adequately wet at all times until disposed of.
(IV) They are Category II nonfriable ACM and the probability is low that the materials will become crumbled, pulverized, or reduced to powder during demolition.
(B) When a facility component that contains, is covered with, or is coated with RACM is being taken out of the facility as a unit or in sections:
(I) Adequately wet all RACM exposed during cutting or disjointing operations; and
(II) Carefully lower each unit or section to the floor and to ground level, not dropping, throwing, sliding, or otherwise damaging or disturbing the RACM.
(C) When RACM is stripped from a facility component while it remains in place in the facility, adequately wet the RACM during the stripping operation.
(I) In renovation operations, wetting is not required if:
(1.) The owner or operator has obtained prior written approval from the Administrator based on a written application that wetting to comply with this paragraph would unavoidably damage equipment or present a safety hazard; and
STATE OF WYOMING NOTIFICATION OF DEMOLITION AND RENOVATION
| I. FACILITY DESCRIPTION (INCLUDE BUILDING NAME, NUMBER, AND FLOOR OR ROOM NUMBER) | |||||
|---|---|---|---|---|---|
| BLDG NAME: | |||||
| ADDRESS: | |||||
| CITY: | STATE: | CONTACT: | |||
| SITE DESCRIPTION (type of material being removed) | |||||
| II. FACILITY INFORMATION (IDENTIFY OWNER, REMOVAL CONTRACTOR, AND OTHER OPERATOR) | |||||
| OWNER NAME: | |||||
| ADDRESS: | |||||
| CITY: | STATE: | ZIP: | |||
| CONTACT: | TEL: | ||||
| REMOVAL CONTRACTOR: | |||||
| ADDRESS: | |||||
| CITY: | STATE: | ZIP: | |||
| CONTACT: | TEL: | ||||
| OTHER OPERATOR: | |||||
| ADDRESS: | |||||
| CITY: | STATE: | ZIP: | |||
| CONTACT: | TEL: | ||||
| BUILDING SIZE: | NUM OF FLOORS: | AGE IN YEARS: | |||
| PRESENT USE: | PRIOR USE: | ||||
| III. TYPE OF OPERATION (D=DEMO O=ORDERED DEMO R=RENOVATION E=EMER. RENOVATION): | |||||
| IV. IS ASBESTOS PRESENT? (YES/NO) | |||||
| V. PROCEDURE, INCLUDING ANALYTICAL METHOD, IF APPROPRIATE, USED TO DETECT THE PRESENCE OF ASBESTOS MATERIAL: | |||||
| VI. SCHEDULED DATES ASBESTOS REMOVAL (MM/DD/YY) | START: | COMPLETE: | |||
| VII. SCHEDULED DATES DEMO/RENOVATION (MM/DD/YY) | START: | COMPLETE: | |||
| VIII. SCHEDULED WORK HOURS: | START: | COMPLETE: | |||
| IX. APPROXIMATE AMOUNT OF ASBESTOS, INCLUDING: 1. REGULATED ACM TO BE REMOVED 2. CATEGORY I ACM NOT REMOVED 3. CATEGORY II ACM NOT REMOVED | RACM TO BE REMOVED | NONFRIABLE ASBESTOS MATERIAL TO BE REMOVED | NONFRIABLE ASBESTOS MATERIAL NOT TO BE REMOVED | ||
| CAT I | CAT II | CAT I | CAT II | ||
| PIPES | |||||
| SURFACE AREA | |||||
| VOL. RACM OFF FACILITY COMPONENT | |||||
| X. DESCRIPTION OF PLANNED DEMOLITION OR RENOVATION WORK, AND METHOD(S) TO BE USED: | |||||
| XI. DESCRIPTION OF WORK PRACTICES AND ENGINEERING CONTROLS TO BE USED TO PREVENT EMISSIONS OF ASBESTOS AT THE DEMOLITION AND RENOVATION SITE: |
Figure 3. NOTIFICATION OF DEMOLITION AND RENOVATION (continued)
| XII. TYPE OF NOTIFICATION (O=ORIGINAL R=REVISED C=CANCELED): | WPR Notice? | |
|---|---|---|
| XIII. WASTE TRANSPORTER #1 | ||
| NAME: | ||
| ADDRESS: | ||
| CITY: | STATE: | ZIP: |
| CONTACT PERSON: | TELEPHONE: | |
| WASTE TRANSPORTER #2 | ||
| NAME: | ||
| ADDRESS: | ||
| CITY: | STATE: | ZIP: |
| CONTACT PERSON: | TELEPHONE: | |
| XIV. WASTE DISPOSAL SITE | ||
| NAME: | ||
| LOCATION: | ||
| CITY: | STATE: | ZIP: |
| TELEPHONE: | CONTACT PERSON: | |
| XV. IF DEMOLITION ORDERED BY A GOVERNMENT AGENCY, PLEASE IDENTIFY THE AGENCY BELOW: | ||
| NAME: | TITLE: | |
| AUTHORITY: | ||
| DATE OF ORDER (MM/DD/YY): | DATE ORDERED TO BEGIN (MM/DD/YY): | |
| XVI. FOR EMERGENCY RENOVATIONS | ||
| DATE AND HOUR OF EMERGENCY (MM/DD/YY): | ||
| DESCRIPTION OF THE SUDDEN, UNEXPECTED EVENT: | ||
| EXPLANATION OF HOW THE EVENT CAUSED UNSAFE CONDITIONS OR WOULD CAUSE EQUIPMENT DAMAGE OR AN UNREASONABLE FINANCIAL BURDEN: | ||
| XVII. DESCRIPTION OF PROCEDURES TO BE FOLLOWED IN THE EVENT THAT UNEXPECTED ASBESTOS IS FOUND OR PREVIOUSLY NONFRIABLE ASBESTOS MATERIAL BECOMES CRUMBLED, PULVERIZED, OR REDUCED TO POWDER: | ||
| XVIII. I CERTIFY THAT AN INDIVIDUAL TRAINED IN THE PROVISIONS OF THIS REGULATION (40 CFR PART 61, SUBPART M) WILL BE ON-SITE DURING THE DEMOLITION OR RENOVATION AND EVIDENCE THAT THE REQUIRED TRAINING HAS BEEN ACCOMPLISHED BY THIS PERSON WILL BE AVAILABLE FOR INSPECTION DURING NORMAL BUSINESS HOURS (REQUIRED 1 YEAR AFTER PROMULGATION). | ||
| ______ | (SIGNATURE OF OWNER/OPERATOR) (DATE) | |
| XIX. I CERTIFY THAT THE ABOVE INFORMATION IS CORRECT. | ||
| ______ | (SIGNATURE OF OWNER/OPERATOR) (DATE) |
(2.) The owner or operator uses one of the following emission control methods:
a. A local exhaust ventilation and collection system designed and operated to capture the particulate asbestos material produced by the stripping and removal of the asbestos materials. The system must exhibit no visible emissions to the outside air or be designed and operated in accordance with the requirements in paragraph (o).
b. A glove-bag system designed and operated to contain the particulate asbestos material produced by the stripping of the asbestos materials.
c. Leak-tight wrapping to contain all RACM prior to dismantlement.
(II) In renovation operations where wetting would result in equipment damage or a safety hazard, and the methods allowed in paragraph (i)(iii)(C)(I) cannot be used, another method may be used after obtaining written approval from the Administrator based upon a determination that it is equivalent to wetting in controlling emissions or to the methods allowed in paragraph (i)(iii)(C)(I).
(III) A copy of the Administrator’s written approval shall be kept at the worksite and made available for inspection.
(D) After a facility component covered with, coated with, or containing RACM has been taken out of the facility as a unit or in sections pursuant to paragraph (i)(iii)(B), it shall be stripped or contained in leak-tight wrapping, except as described in paragraph (i)(iii)(E). If stripped, either:
(I) Adequately wet the RACM during stripping; or
(II) Use a local exhaust ventilation and collection system designed and operated to capture the particulate asbestos material produced by the stripping. The system must exhibit no visible emissions to the outside air or be designed and operated in accordance with the requirements in paragraph (o).
(E) For large facility components such as reactor vessels, large tanks, and steam generators, but not beams (which must be handled in accordance with paragraphs (i)(iii)(B), (C), and (D)), the RACM is not required to be stripped if the following requirements are met:
(I) The component is removed, transported, stored, disposed of, or reused without disturbing or damaging the RACM.
(II) The component is encased in a leak-tight wrapping.
(III) The leak-tight wrapping is labeled according to paragraphs (m)(iv) during all loading and unloading operations and during storage.
(F) For all RACM, including material that has been removed or stripped:
(I) Adequately wet the material and ensure that it remains wet until collected and contained or treated in preparation for disposal in accordance with paragraph (m).
(II) Carefully lower the material to the ground and floor, not dropping, throwing, sliding, or otherwise damaging or disturbing the material.
(III) Transport the material to the ground via leak-tight chutes or containers if it has been removed or stripped more than 50 feet above ground level and was not removed as units or in sections.
(IV) RACM contained in leak-tight wrapping that has been removed in accordance with paragraphs (i)(iii)(D) and (i)(iii)(C)(I)(2.)c. need not be wetted.
(G) When the temperature at the point of wetting is below 0°C (32°F):
(I) The owner or operator need not comply with paragraph (i)(iii)(B)(I) and the wetting provisions of paragraph (i)(iii)(C).
(II) The owner or operator shall remove facility components containing, coated with, or covered with RACM as units or in sections to the maximum extent possible.
(III) During periods when wetting operations are suspended due to freezing temperatures, the owner or operator must record the temperature in the area containing the facility components at the beginning, middle, and end of each workday and keep daily temperature records available for inspection by the Administrator during normal business hours at the demolition or renovation site. The owner or operator shall retain the temperature records for at least 2 years.
(H) No RACM shall be stripped, removed, or otherwise handled or disturbed at a facility regulated by this section unless the individuals supervising and performing the operation have been trained in the provisions of this regulation and the means of complying with them. Asbestos School Hazard Abatement Reauthorization Act (ASHARA) training will be acceptable to meet this requirement. Every year, the individuals supervising and performing asbestos operations shall receive refresher training in the provisions of this regulation. The required training shall include as a minimum: applicability; notifications; material identification; control procedures for removals including, at least, wetting, local exhaust ventilation, negative pressure enclosures, glove-bag procedures, and High Efficiency Particulate Air (HEPA) filters; waste disposal work practices; reporting and recordkeeping; and asbestos hazards and worker protection. Evidence that the required training has been completed shall be posted and made available for inspection by the Administrator at the demolition or renovation site.
(I) For facilities described in paragraph (i)(i)(C), adequately wet the portion of the facility that contains RACM during the wrecking operation.
(J) If a facility is demolished by intentional burning, all RACM including Category I and Category II nonfriable ACM must be removed in accordance with the NESHAP before burning.
(j) Standard for Spraying.
The owner or operator of an operation in which asbestos-containing materials are spray applied shall comply with the following requirements:
(i) For spray-on application on buildings, structures, pipes, and conduits do not use material containing more than 1 percent asbestos as determined using the method specified in 40 CFR Part 763 Appendix E, Section 1, Polarized Light Microscopy, except as provided in paragraph (j)(iii).
(ii) For spray-on application of materials that contain more than 1 percent asbestos as determined using the method specified in 40 CFR Part 763 Appendix E, Section 1, Polarized Light Microscopy, on equipment and machinery, except as provided in paragraph (j)(iii):
(A) Notify the Administrator at least 20 days before beginning the spraying operation. Include the following information in the notice:
(I) Name and address of owner or operator.
(II) Location of spraying operation.
(III) Procedures to be followed to meet the requirements of paragraph (j).
(B) Discharge no visible emissions to the outside air from spray-on application of the asbestos-containing material or use the methods specified by paragraph (o) to clean emissions containing particulate asbestos material before they escape to, or are vented to, the outside air.
(iii) The requirements of paragraphs (j)(i) and (j)(ii) do not apply to the spray-on application of materials where the asbestos fibers in the materials are encapsulated with a bituminous or resinous binder during spraying and the materials are not friable after drying.
(k) Standard for Fabricating.
(i) Applicability. This section applies to the following fabrication operations using commercial asbestos:
(A) The fabrication of cement building products.
(B) The fabrication of friction products, except those operations that primarily install asbestos friction materials on motor vehicles.
(C) The fabrication of cement on silicate board for ventilation hoods; ovens; electrical panels; laboratory furniture, bulkheads, partitions, and ceilings for marine construction; and flow control devices for the molten metal industry.
(ii) Standard. Each owner or operator of any of the fabricating operations to which this section applies shall either:
(A) Discharge no visible emissions to the outside air from any of the operations or from any building or structure in which they are conducted or from any other fugitive sources; or
(B) Use the methods specified by paragraph (o) to clean emissions containing particulate asbestos material before they escape to, or are vented to, the outside air.
(C) Monitor each potential source of asbestos emissions from any part of the fabricating facility, including air cleaning devices, process equipment, and buildings that house equipment for material processing and handling, at least once a day, during daylight hours, for visible emissions to the outside air during periods of operation. The monitoring shall be by visual observation of at least 15 seconds duration per source of emission.
(D) Inspect each air cleaning device at least once each week for proper operation and for changes that signal the potential for malfunctions, including, to the maximum extent possible without dismantling other than opening the device, the presence of tears, holes, and abrasions in the filter bags and for dust deposits on the clean side of bags. For air cleaning devices that cannot be inspected on a weekly basis according to this paragraph, submit to the Administrator, and revise as necessary, a written maintenance plan to include, at a minimum, the following:
(I) Maintenance schedule.
(II) Recordkeeping plan.
(E) Maintain records of the results of visible emission monitoring and air cleaning device inspections using a format similar to that shown in Figures 1 and 2 and include the following:
(I) Date and time of each inspection.
(II) Presence or absence of visible emissions.
(III) Condition of fabric filters, including presence of any tears, holes, and abrasions.
(IV) Presence of dust deposits on clean side of fabric filters.
(V) Brief description of corrective actions taken, including date and time.
(VI) Daily hours of operation for each air cleaning device.
(F) Furnish upon request and make available at the affected facility during normal business hours for inspection by the Administrator, all records required under this paragraph.
(G) Retain a copy of all monitoring and inspection records for at least 2 years.
(H) Submit quarterly a copy of the visible emission monitoring records to the Administrator if visible emissions occurred during the report period. Quarterly reports shall be postmarked by the 30th day following the end of the calendar quarter.
(I) Standard for Insulating Materials. No owner or operator of a facility may install or reinstall on a facility component any insulating materials that contain commercial asbestos if the materials are either molded and friable or wet-applied and friable after drying. The provisions of this paragraph do not apply to spray-applied insulating materials regulated under paragraph (j).
(m) Standard for Waste Disposal for Non-facilities, Manufacturing, Demolition, Renovation, Spraying, and Fabricating. Each owner or operator of any source covered under the provisions of paragraphs (g), (h), (i), (j), or (k) shall meet the requirements of the Wyoming Department of Environmental Quality, Solid & Hazardous Waste Division, or, at a minimum, the requirements of the following:
(i) Discharge no visible emissions to the outside air during the collection, processing (including incineration), packaging, or transporting of any asbestos-containing waste material generated by the source, or use one of the emission control and waste treatment methods specified in paragraphs (m)(i)(A) through (D).
(A) Adequately wet asbestos-containing waste material as follows:
(I) Mix control device asbestos waste to form a slurry; adequately wet other asbestos-containing waste material; and
(II) Discharge no visible emissions to the outside air from collection, mixing, wetting, and handling operations, or use the methods specified by paragraph (o) to clean emissions containing particulate asbestos material before they escape to, or are vented to, the outside air; and
(III) After wetting, seal all asbestos-containing waste material in leak-tight containers while wet; or, for materials that will not fit into containers without additional breaking, put materials into leak-tight wrapping; and
(IV) Label the containers or wrapped materials specified in paragraph (m)(i)(A)(III) using warning labels specified by Occupational Safety and Health Standards of the Department of Labor, Occupational Safety and Health Administration (OSHA) under 29 CFR § 1910.1001(j)(4) or § 1926.1101(k)(8). The labels shall be printed in letters of sufficient size and contrast so as to be readily visible and legible.
(V) For asbestos-containing waste material to be transported off the facility site, label containers or wrapped materials with the name of the waste generator and the location at which the waste was generated.
(B) Process asbestos-containing waste material into nonfriable forms as follows:
(I) Form all asbestos-containing waste material into nonfriable pellets or other shapes;
(II) Discharge no visible emissions to the outside air from collection and processing operations, including incineration, or use the method specified by paragraph (o) to clean emissions containing particulate asbestos materials before they escape to, or are vented to, the outside air.
(C) For facilities demolished where the RACM is not removed prior to demolition, adequately wet asbestos-containing waste material at all times after demolition and keep wet during handling and loading for transport to a disposal site. Asbestos-containing waste materials covered by this paragraph do not have to be sealed in leak-tight containers or wrapping but may be transported and disposed of in bulk.
(D) Use an alternative emission control and waste treatment method that has received prior written approval by the Administrator.
(E) As applied to demolition and renovation, the requirements of paragraph (m)(i) do not apply to Category I and Category II nonfriable ACM waste that did not become crumbled, pulverized, or reduced to powder.
(ii) All asbestos-containing waste material shall be deposited as soon as is practical by the waste generator at:
(A) A waste disposal site operated in accordance with the provisions of paragraph (q), or (B) An EPA-approved site that converts RACM and asbestos-containing waste material into nonasbestos (asbestos-free) material according to the provisions of paragraph (r).
(C) The requirements of paragraph (m)(ii) do not apply to Category I nonfriable ACM that is not RACM.
(iii) Mark vehicles used to transport asbestos-containing waste material during the loading and unloading of waste so that the signs are visible. The markings must:
(A) Be displayed in such a manner and location that a person can easily read the legend.
(B) Conform to the requirements for 51 cm X 36 cm (20 in X 14 in) upright format signs specified in 29 CFR § 1910.145(d)(2) and this paragraph; and
(C) Display the following legend in the lower panel with letter sizes and styles of a visibility at least equal to those specified below.
DANGER ASBESTOS DUST HAZARD CANCER AND LUNG DISEASE HAZARD Authorized Personnel Only
2.5 cm (1 inch) Sans Serif, Gothic or Block 2.5 cm (1 inch) Sans Serif, Gothic or Block 1.9 cm (3/4 inch) Sans Serif, Gothic or Block 14 Point Gothic
Spacing between any two lines must be at least equal to the height of the upper of the two lines.
(iv) For All Asbestos-Containing Waste Material Transported Off the Facility Site:
(A) Maintain waste shipment records, using a form similar to that shown in Figure 4, and include the following information:
(I) The name and telephone number of the disposal site operator.
(II) The name and physical site location of the disposal site.
(III) The date transported.
(IV) The name, address, and telephone number of the transporter(s).
Figure 4. Waste Shipment Record
| GENERATOR | ||
|---|---|---|
| 1. Work site name and mailing address | Owner's name | Owner's telephone no. |
| 2. Operator's name and address | Operator's telephone no. | |
| 3. Waste disposal site (WDS) name, mailing address, and physical site location | WDS telephone no. | |
| 4. Name and address of responsible agency | ||
| 5. Description of materials | 6. Containers No. Type | 7. Total quantity m³ (yd³) |
| 8. Special handling instructions and additional information | ||
| 9. OPERATOR'S CERTIFICATION: I hereby declare that the contents of this consignment are fully and accurately described above by proper shipping name and are classified, packed, marked, and labeled, and are in all respects in proper condition for transport by highway according to applicable international and government regulations. | ||
| Printed/typed name & title | Signature | Month Day Year |
| Transporter | ||
| 10. Transporter 1 (Acknowledgment of receipt of materials) | ||
| Printed/typed name & title Address and telephone no. | Signature | Month Day Year |
| 11. Transporter 2 (Acknowledgment of receipt of materials) | ||
| Printed/typed name & title Address and telephone no. | Signature | Month Day Year |
| Disposal Site | ||
| 12. Discrepancy indication space | ||
| 13. Waste disposal site owner or operator: Certification of receipt of asbestos materials covered by this manifest except as noted in item 12. | ||
| Printed/typed name & title | Signature | Month Day Year |
(V) A certification that the contents of this consignment are fully and accurately described by proper shipping name and are classified, packed, marked, and labeled, and are in all respects in proper condition for transport by highway according to applicable international and governmental regulations.
(B) Provide a copy of the waste shipment record, described in paragraph (m)(iv)(A), to the disposal site owners or operators at the same time as the asbestos-containing waste material is delivered to the disposal site.
(C) For waste shipments where a copy of the waste shipment record, signed by the owner or operator of the designated disposal site, is not received by the waste generator within 35 days of the date the waste was accepted by the initial transporter, contact the transporter and/or the owner or operator of the designated disposal site to determine the status of the waste shipment.
(D) Report in writing to the Wyoming Department of Environmental Quality, Air Quality Division, if a copy of the waste shipment record, signed by the owner or operator of the designated waste disposal site, is not received by the waste generator within 45 days of the date the waste was accepted by the initial transporter. Include in the report the following information:
(I) A copy of the waste shipment record for which a confirmation of delivery was not received, and
(II) A cover letter signed by the waste generator explaining the efforts taken to locate the asbestos waste shipment and the results of those efforts.
(E) Retain a copy of all waste shipment records, including a copy of the waste shipment record signed by the owner or operator of the designated waste disposal site, for at least 2 years.
(v) Furnish upon request, and make available for inspection by the Administrator, all records required under this section.
(n) Standard for Inactive Waste Disposal Sites for Manufacturing and Fabricating Operations. Each owner or operator of any inactive waste disposal site that was operated by sources covered under paragraphs (h) or (k) and received deposits of asbestos-containing waste material generated by the sources, shall meet the requirements of the Wyoming Department of Environmental Quality, Solid & Hazardous Waste Division, or at a minimum:
(i) Comply With One of the Following:
(A) Either discharge no visible emissions to the outside air from an inactive waste disposal site subject to the paragraph; or
(B) Cover the asbestos-containing waste material with at least 15 centimeters (6 inches) of compacted nonasbestos-containing material, and grow and maintain a cover of vegetation on the area adequate to prevent exposure of the asbestos-containing waste material. In desert areas where vegetation would be difficult to maintain, at least 8 additional centimeters (3 inches) of well-graded, nonasbestos crushed rock may be placed on top of the final cover instead of vegetation and maintained to prevent emissions; or
(C) Cover the asbestos-containing waste material with at least 60 centimeters (2 feet) of compacted nonasbestos-containing material, and maintain it to prevent exposure of the asbestos-containing waste; or
(D) For inactive waste disposal sites for asbestos tailings, a resinous or petroleum-based dust suppression agent that effectively binds dust to control surface air emissions may be used instead of the methods in paragraphs (n)(i)(A), (B), and (C). Use the agent in the manner and frequency recommended for the particular asbestos tailings by the manufacturer of the dust suppression agent to achieve and maintain dust control. Obtain prior written approval of the Administrator to use other equally effective dust suppression agents. For purposes of this paragraph, any used, spent, or other waste oil is not considered a dust suppression agent.
(ii) Unless a natural barrier adequately deters access by the general public, install and maintain warning signs and fencing as follows, or comply with paragraph (n)(i)(B) or (n)(i)(C).
(A) Display warning signs at all entrances and at intervals of 100 m (328 feet) or less along the property line of the site or along the perimeter of the sections of the site where asbestos-containing waste material was deposited. The warning signs must:
(I) Be posted in such a manner and location that a person can easily read the legend;
(II) Conform to the requirements of 51 cm x 36 cm (20' x 14') upright format signs specified in 29 CFR § 1910.145(d)(4) and this paragraph; and
(III) Display the following legend in the lower panel with letter sizes and styles of a visibility at least equal to those specified in this paragraph.
DO NOT CREATE DUST
2.5 cm (1 inch) Sans Serif, Gothic or Block
1.9 cm (3/4 inch) Sans Serif, Gothic or Block
Spacing between any two lines must be at least equal to the height of the upper of the two lines.
(B) Fence the perimeter of the site in a manner adequate to deter access by the general public.
(C) When requesting a determination on whether a natural barrier adequately deters public access, supply information enabling the Administrator to determine whether a fence or a natural barrier adequately deters access by the general public.
(iii) The owner or operator may use an alternative control method that has received prior approval of the Administrator rather than comply with the requirements of paragraph (n)(i) or (n)(ii).
(iv) Notify the Administrator in writing at least 45 days prior to excavating or otherwise disturbing any asbestos-containing waste material that has been deposited at a waste disposal site under this section, and follow the procedures specified in the notification. If the excavation will begin on a date other than the one contained in the original notice, notice of the new start date must be provided to the Administrator at least 10 working days before excavation begins and in no event shall excavation begin earlier than the date specified in the original notification. Include the following information in the notice:
(A) Scheduled starting and completion dates.
(B) Reason for disturbing the waste.
(C) Procedures to be used to control emissions during the excavation, storage, transport, and ultimate disposal of the excavated asbestos-containing waste material. If deemed necessary, the Administrator may require changes in the emission control procedures to be used.
(D) Location of any temporary storage site and the final disposal site.
(v) Within 60 days of a site becoming inactive and after the effective date of this subpart, record, in accordance with State law, a notation on the deed to the facility property and on any other instrument that would normally be examined during a title search; this notation will in perpetuity notify any potential purchaser of the property that:
(A) The land has been used for the disposal of asbestos-containing waste material;
(B) The survey plot and record of the location and quantity of asbestos-containing waste disposed of within the disposal site required in paragraph (q)(vi) have been filed with the Administrator; and (C) The site is subject to WAQSR Chapter 3, Section 8 and to 40 CFR Part 61, Subpart M.
(o) Air Cleaning.
(i) The owner or operator who uses air cleaning, as specified in paragraphs (h)(ii)(B), (i)(iii)(C)(I)(2.)a., (i)(iii)(D)(II), (j)(ii)(B), (k)(ii)(B), (m)(i)(A)(II), (m)(i)(B)(II) and (r)(v) shall:
(A) Use fabric filter collection devices, except as noted in paragraph (o)(ii), doing all of the following:
(I) Ensuring that the airflow permeability, as determined by ASTM Method D737-04 Test Method for Air Permeability of Textile Fabrics, does not exceed 9 m³/min/m² (30 ft³/min/ft²) for woven fabrics or 11 m³/min/m² (35 ft³/min/ft²) for felted fabrics, except that 12 m³/min/m² (40 ft³/min/ft²) for woven and 14 m³/min/m² (45 ft³/min/ft²) for felted fabrics is allowed for filtering air from asbestos ore dryers;
(II) Ensuring that felted fabric weighs at least 475 grams per square meter (14 ounces per square yard) and is at least 1.6 millimeters (one-sixteenth inch) thick throughout; and
(III) Avoiding the use of synthetic fabrics that contain fill yarn other than that which is spun.
(B) Properly install, use, operate, and maintain all air-cleaning equipment authorized by this paragraph. Bypass devices may be used only during upset or emergency conditions and then only for so long as it takes to shut down the operation generating the particulate asbestos material.
(C) For fabric filter collection devices installed after January 10, 1989, provide for easy inspection for faulty bags.
(ii) There are the following exceptions to paragraph (o)(i)(A):
(A) After January 10, 1989, if the use of fabric creates a fire or explosion hazard, or the Administrator determines that a fabric filter is not feasible, the Administrator may authorize as a substitute the use of wet collectors designed to operate with a unit contacting energy of at least 9.95 kilopascals (40 inches water gage pressure).
(B) Use a HEPA filter that is certified to be at least 99.97 percent efficient for 0.3 micron particles.
(C) The Administrator may authorize the use of filtering equipment other than described in paragraphs (o)(i)(A) and (o)(ii)(A) and (B) if the owner or operator demonstrates to the Administrator’s satisfaction that it is equivalent to the described equipment in filtering particulate asbestos material.
(i) Any new source to which this section applies (with the exception of sources subject to paragraphs (i), (j), and (l)), which has an initial startup date preceding the effective date of this revision, shall provide the following information to the Administrator postmarked or delivered within 90 days of the effective date. In the case of a new source that does not have an initial startup date preceding the effective date, the information shall be provided, postmarked or delivered, within 90 days of the initial startup date. Any owner or operator of an existing source shall provide the following information to the Administrator within 90 days of the effective date of this subpart unless the owner or operator of the existing source has previously provided this information to the Administrator. Any changes in the information provided by any existing source shall be provided to the Administrator, postmarked or delivered, within 30 days after the change.
(A) A description of the emission control equipment used for each process; and
(I) If the fabric device uses a woven fabric, the airflow permeability in m³/min/m² and; if the fabric is synthetic, whether the fill yarn is spun or not spun; and
(II) If the fabric filter device uses a felted fabric, the density in g/m², the minimum thickness in inches and the airflow permeability in m³/min/m².
(B) If a fabric filter device is used to control emissions,
(I) The airflow permeability in m³/min/m² (ft³/min/ft²) if the fabric filter device uses a woven fabric, and, if the fabric is synthetic, whether the fill yarn is spun or not spun; and
(II) If the fabric filter device uses a felted fabric, the density in g/m² (oz/yd²), the minimum thickness in millimeters (inches), and the airflow permeability in m³/min/m² (ft³/min/ft²).
(C) If a HEPA filter is used to control emissions, the certified efficiency.
(D) For sources subject to paragraph (m):
(I) A brief description of each process that generates asbestos-containing waste material;
(II) The average volume of asbestos-containing waste material disposed of measured in m³/day (yd³/day);
(III) The emission control methods used in all stages of waste disposal; and
(IV) The type of disposal site or incineration site used for ultimate disposal, the name of the site operator, and the name and location of the disposal site.
(E) For sources subject to paragraphs (n) and (q):
(I) A brief description of the site; and
(II) The method or methods used to comply with the standard, or alternate procedures to be used.
(ii) The information required by paragraph (p)(i) must accompany the information required by 40 CFR Part 61, subpart A, 61.10. Active waste disposal sites subject to paragraph (q) shall also comply with this provision. Demolition and renovation, spraying, and insulating materials are exempted from the requirements of 40 CFR Part 61.10(a). The information described in this paragraph must be reported using the format of Appendix A of CFR 40 Part 61 as a guide.
(q) Standard for Active Waste Disposal Sites. Each owner or operator of an active waste disposal site that receives asbestos-containing waste material from a source covered under paragraphs (m) or (r) shall meet the requirements of the Wyoming Department of Environmental Quality, Solid & Hazardous Waste Division, or at a minimum the following:
(i) Either there must be no visible emissions to the outside air from any active waste disposal site where asbestos-containing waste material has been deposited, or the requirements of paragraph (q)(iii) or (q)(iv) must be met.
(ii) Unless a natural barrier adequately deters access by the general public, either warning signs and fencing must be installed and maintained as follows, or the requirements of paragraph (q)(iii)(A) must be met.
(A) Warning signs must be displayed at all entrances and at intervals of 100 m (330 ft) or less along the property line of the site or along the perimeter of the sections of the site where asbestos-containing waste material is deposited. The warning signs must:
(I) Be posted in such a manner and location that a person can easily read the legend;
(II) Conform to the requirements of 51 cm x 36 cm (20' x 14') upright format signs specified in 29 CFR § 1910.145(d)(4) and this paragraph; and
(III) Display the following legend in the lower panel with letter sizes and styles of a visibility at least equal to those specified below.
ASBESTOS WASTE DISPOSAL SITE DO NOT CREATE DUST Breathing Asbestos is Hazardous to Your Health
2.5 cm (1 inch) Sans Serif, Gothic or Block 1.9 cm (3/4 inch) Sans Serif, Gothic or Block 14 point Gothic
Spacing between any two lines must be at least equal to the height of the upper of the two lines.
(B) The perimeter of the disposal site must be fenced in a manner adequate to deter access by the general public.
(C) Upon request and supply of appropriate information, the Administrator will determine whether a fence or a natural barrier adequately deters access by the general public.
(iii) Rather than meet the no visible emission requirement of paragraph (q)(i), at the end of each operating day, or at least once every 24-hour period while the site is in continuous operation, the asbestos-containing waste material that has been deposited at the site during the operating day or previous 24-hour period shall:
(A) Be covered with at least 15 centimeters (6 inches) of compacted nonasbestos-containing material, or
(B) Be covered with a resinous or petroleum-based dust suppression agent that effectively binds dust and controls wind erosion. Such an agent shall be used in the manner and frequency recommended for the particular dust by the dust suppression agent manufacturer to achieve and maintain dust control. Other equally effective dust suppression agents may be used upon prior approval by the Administrator. For purposes of this paragraph, any used, spent, or other waste oil is not considered a dust suppression agent.
(iv) Rather than meet the no visible emission requirement of paragraph (q)(i), use an alternative emissions control method that has received prior written approval by the Administrator.
(v) For all asbestos-containing waste material received, the owner or operator of the active waste disposal site shall:
(A) Maintain waste shipment records, using a form similar to that shown in Figure 4, and include the following information:
(I) The name, address, and telephone number of the waste generator. (II) The name, address, and telephone number of the transporter(s). (III) The quantity of the asbestos-containing waste material in cubic meters (cubic yards). (IV) The presence of improperly enclosed or uncovered waste, or any asbestos-containing waste material not sealed in leak-tight containers. (V) The date of the receipt.
(B) Upon discovering the presence of a significant amount of improperly enclosed or uncovered waste, report in writing by the following working day to the local, State, or EPA Regional office responsible for administering the asbestos NESHAP program for the waste generator (identified in the waste shipment record), and, if that office is outside the State of Wyoming, also report in writing by the following working day to the Wyoming Department of Environmental Quality, Air Quality Division. Submit a copy of the waste shipment record along with the report.
(C) As soon as possible and no longer than 30 days after receipt of the waste, send a copy of the signed waste shipment record to the waste generator.
(D) Upon discovering a discrepancy between the quantity of waste designated on the waste shipment records and the quantity actually received, attempt to reconcile the discrepancy with the waste generator. If the discrepancy is not resolved within 15 days after receiving the waste, immediately report in writing to the local, State, or EPA Regional office responsible for administering the asbestos NESHAP program for the waste generator (identified in the waste shipment record), and, if that office is outside the State of Wyoming, also report in writing to the Wyoming Department of Environmental Quality, Air Quality Division. Describe the discrepancy and attempts to reconcile it, and submit a copy of the waste shipment record along with the report.
(E) Retain a copy of all records and reports required by this paragraph for at least 2 years.
(vi) Maintain, until closure, records of the location, depth and area, and quantity in cubic meters (cubic yards) of asbestos-containing waste material within the disposal site on a map or diagram of the disposal area.
(vii) Upon closure, comply with all the provisions of paragraph (n).
(viii) Submit to the Administrator, upon closure of the facility, a copy of records of asbestos waste disposal locations and quantities.
(ix) Furnish upon request, and make available during normal business hours for inspection by the Administrator, all records required under this paragraph.
(x) Notify the Administrator in writing at least 45 days prior to excavating or otherwise disturbing any asbestos-containing waste material that has been deposited at a waste disposal site and is covered. If the excavation will begin on a date other than the one contained in the original notice, notice of the new start date must be provided at least 10 working days before excavation begins and in no event shall excavation begin earlier than the date specified in the original notification. Include the following information in the notice.
(A) Scheduled starting and completion dates.
(B) Reason for disturbing the waste.
(C) Procedures to be used to control emissions during the excavation, storage, transport, and ultimate disposal of the excavated asbestos-containing waste material. If deemed necessary, the Administrator may require changes in the emission control procedures to be used.
(D) Location of any temporary storage site and the final disposal site.
(r) Standard for Operations That Convert Asbestos-Containing Waste Material Into Nonasbestos (Asbestos-Free) Material. Each owner or operator of an operation that converts RACM and asbestos-containing waste material into nonasbestos (asbestos-free) material shall:
(i) Obtain the prior written approval of the Administrator to construct the facility. To obtain approval, the owner or operator shall provide the Administrator with the following information:
(A) Application to construct pursuant to 40 CFR § 61.07.
(B) In addition to the information requirements of 40 CFR § 61.07(b)(3), a
(I) Description of waste feed handling and temporary storage.
(II) Description of process operating conditions.
(III) Description of the handling and temporary storage of the end product.
(IV) Description of the protocol to be followed when analyzing output materials by transmission electron microscopy.
(C) Performance test protocol, including provisions for obtaining information required under paragraph (r)(ii).
(D) The Administrator may require that a demonstration of the process be performed prior to approval of the application to construct.
(ii) Conduct a Start-up Performance Test. Test Results Shall Include:
(A) A detailed description of the types and quantities of nonasbestos material, RACM, and asbestos-containing waste material processed, e.g., asbestos cement products, friable asbestos insulation, plaster, wood, plastic, wire, etc. Test feed is to include the full range of materials that will be encountered in actual operation of the process.
(B) Results of analyses, using polarized light microscopy, that document the asbestos content of the wastes processed.
(C) Results of analyses, using transmission electron microscopy, that document that the output materials are free of asbestos. Samples for analysis are to be collected as 8-hour composite samples (one 200-gram (7-ounce) sample per hour), beginning with the initial introduction of RACM or asbestos-containing waste material and continuing until the end of the performance test.
(D) A description of operation parameters, such as temperature and residence time, defining the full range over which the process is expected to operate to produce nonasbestos (asbestos-free) materials. Specify the limits for each operating parameter within which the process will produce nonasbestos (asbestos-free) materials.
(E) The length of the test.
(iii) During the initial 90 days of operation,
(A) Continuously monitor and log the operating parameters identified during start-up performance tests that are intended to ensure the production of nonasbestos (asbestos-free) output material.
(B) Monitor input materials to ensure that they are consistent with the test feed materials described during start-up performance tests in paragraph (r)(ii)(A).
(C) Collect and analyze samples, taken as 10-day composite samples (one 200-gram (7-ounce) sample collected every 8 hours of operation) of all output material for the presence of asbestos. Composite samples may be for fewer than 10 days. Transmission electron microscopy (TEM) shall be used to analyze the output material for the presence of asbestos. During the initial 90-day period, all output materials must be stored on-site until analysis shows the material to be asbestos-free or disposed of as asbestos-containing waste material according to paragraph (m).
(iv) After the initial 90 days of operation, (A) Continuously monitor and record the operating parameters identified during start-up performance testing and any subsequent performance testing. Any output produced during a period of deviation from the range of operating conditions established to ensure the production of nonasbestos (asbestos-free) output materials shall be:
(I) Disposed of as asbestos-containing waste material according to paragraph (m), or
(II) Recycled as waste feed during process operation within the established range of operation conditions, or
(III) Stored temporarily on-site in a leak-tight container until analyzed for asbestos content. Any product material that is not asbestos-free shall be either disposed of as asbestos-containing waste material or recycled as waste feed to the process.
(B) Collect and analyze monthly composite samples (one 200-gram (7-ounce) sample collected every 8 hours of operation) of the output material. Transmission electron microscopy shall be used to analyze the output material for the presence of asbestos.
(v) Discharge no visible emissions to the outside air from any part of the operation, or use the methods specified in paragraph (o) to clean emissions containing particulate asbestos material before they escape to, or are vented to, the outside air.
(vi) Maintain Records On-site and Include the Following Information:
(A) Results of start-up performance testing and all subsequent performance testing, including operating parameters, feed characteristic, and analyses of output materials.
(B) Results of the composite analyses required during the initial 90 days of operation under paragraph (r)(iii).
(C) Results of the monthly composite analyses required under paragraph (r)(iv).
(D) Results of continuous monitoring and logs of process operating parameters required under paragraph (r)(iii) and (iv).
(E) The information on waste shipments received as required in paragraph (q).
(F) For output materials where no analyses were performed to determine the presence of asbestos, record the name and location of the purchaser or disposal site to which the output materials were sold or deposited, and the date of sale or disposal.
(G) Retain records required by paragraph (r)(vi) for at least 2 years.
(vii) Submit the Following Reports to the Administrator:
(A) A report for each analysis of product composite samples performed during the initial 90 days of operation.
(B) A quarterly report, including the following information concerning activities during each consecutive 3-month period:
(I) Results of analyses of monthly product composite samples.
(II) A description of any deviation from the operating parameters established during performance testing, the duration of the deviation, and steps taken to correct the deviation.
(III) Disposition of any product produced during a period of deviation, including whether it was recycled, disposed of as asbestos-containing waste material, or stored temporarily on-site until analyzed for asbestos content.
(IV) The information on waste disposal activities as required in paragraph (q).
(viii) Nonasbestos (asbestos-free) output material is not subject to any of the provisions of this section. Output materials in which asbestos is detected, or output materials produced when the operating parameters deviated from those established during the start-up performance testing, unless shown by TEM analysis to be asbestos-free, shall be considered to be asbestos-containing waste and shall be handled and disposed of according to paragraphs (m) and (q) or reprocessed while all of the established operating parameters are being met.
(a) Code of Federal Regulations (CFR). All Code of Federal Regulations (CFR), including their Appendices, cited in this Chapter, revised and published as of July 1, 2024, not including any later amendments, are incorporated by reference. Copies of the CFR are available for public inspection and can be obtained at cost from the Department of Environmental Quality, Air Quality Division, Cheyenne Office. Contact information for the Cheyenne Office can be obtained at: http://deq.wyoming.gov/. Copies of the CFR can also be obtained at cost from Government Institutes, 15200 NBN Way, Building B, Blue Ridge Summit, PA 17214, or online at https://ecfr.gov.
(b) American Society for Testing and Materials (ASTM). All ASTM standards cited in this Chapter, revised and published as of July 1, 2024, not including any later amendments, are incorporated by reference. Copies of the ASTM standards are available for public inspection and can be obtained at cost from the Department of Environmental Quality, Air Quality Division, Cheyenne Office. Contact information for the Cheyenne Office can be obtained at:
http://deq.wyoming.gov/. Copies can also be obtained at cost from the American Society for Testing and Materials, 100 Barr Harbor Drive, Post Office Box C700, West Conshohocken, PA 19428-2959, or online at http://www.astm.org/DIGITAL_LIBRARY/index.html