(a) The following devices are subject to the registration requirements of §13.1011of the Code; as authorized by §13.029 of the Code:
- (1) motor fuel dispensers;
- (2) kerosene dispensers;
- (3) LPG meters; and
- (4) scales.
(b) The following devices are subject to the inspection requirements of §13.101(a) of the Code; as authorized by §13.029 of the Code.
- (1) motor fuel dispensers;
- (2) kerosene dispensers;
- (3) LPG meters; and
- (4) scales other than hopper scales, except as provided by §12.14 of this chapter (related to Inspection and Testing Requirements for Hopper Scales).
(c) The following devices and motor fuel metering devices, are subject to the registration and inspection requirements of §§13.1015 - 13.1017 of the Code:
- (1) all motor fuel metering device blends shall be inspected, tested, and calibrated by a Licensed Service Company at least once every two years; and
- (2) only the motor fuel metering device and blends indicated in a complaint shall be inspected, tested and calibrated by a Licensed Service Company at a facility once the department has received three complaints at a facility within a twelve month period or a complaint is received on a facility that has not had a complete calibration of all meters and blends within the past 18 months.
(d) Pursuant to §13.029 of the Code, the following devices are exempt from registration and inspection requirements set forth in §13.1001 and §13.1011 of the Code:
- (1) pharmaceutical scales;
- (2) postal scales;
- (3) belt conveyor scales;
- (4) rail scales; and
- (5) immediate consumption food scales.
Source Note:The provisions of this §12.13 adopted to be effective January 23, 2018, 43 TexReg 340.