A facility may contain one or more single occupancy cells for the temporary holding of violent persons. Violent cells shall include the following features and equipment.
- (1) Furnishings. The cell shall be equipped with a hammock, not less than 2' 3" wide and 6' 3" long, made of an elastic or fibrous fabric. A bench abutting the wall, the length or width of the cell, at least 2' 3" wide and 6' 3" long and not more than 8" above the floor may be provided in lieu of a hammock.
- (2) Plumbing. Flushing type floor drains with outside controls shall be provided.
- (3) Cell Size. Cell shall contain not less than 40 square feet of clear floor space.
- (4) Padding. Walls, floor, door and bench shall be completely covered with a material to protect the inmate from self injury. The type of material used to cover the walls, floor, door and bench shall be fire resistive and nontoxic.
Source Note:The provisions of this §259.742 adopted to be effective April 4, 1999, 24 TexReg 2355.