(a) This subsection contains the procedure used to determine the annual whole application rate (AWAR) for a biosolids that does not cause the annual metal loading rates in Table 4 of §312.43(b)(4) of this title (relating to Metal Limits) to be exceeded. Determine the AWAR using the following procedure.
- (1) Analyze a sample of the biosolids to determine the concentration for each of the metals listed in Table 4 of §312.43 of this title.
- (2) Using the metal concentrations from paragraph (1) of this subsection and the AMLRs from Table 4 of §312.43 of this title, calculate an AWAR for each metal using Equation B.1.
- (3) The AWAR for the biosolids is the lowest AWAR calculated in paragraph (2) of this subsection.
Attached Graphic
- (b) Domestic Septage. The annual whole application rate for domestic septage applied to agricultural land, forest, or a reclamation site shall be equal to or less than the annual whole application rate calculated using Equation B.2.
Attached Graphic
Source Note:The provisions of this §312.49 adopted to be effective October 13, 1995, 20 TexReg 7840; amended to be effective April 23, 2020, 45 TexReg 2542.