- (a) The manufacturer will attach a data plate to each dwelling unit of a residential structure containing industrialized housing and buildings modules and to each appropriate unit of a commercial structure containing industrialized housing and buildings modules. The data plate must be made of a material that will not deteriorate over time and be permanently placed so that it cannot be removed without destruction. The data plate will be placed on or near the electrical distribution panel or in some other easily accessible location as designated in the approved design package.
(b) The data plate must contain, as a minimum, the following information:
- (1) the manufacturer's name, registration number, and address;
- (2) the serial or identification number of the unit;
- (3) the State decal numbers;
- (4) the name and date of applicable codes;
- (5) an identification of permissible type of gas for appliances;
- (6) the maximum snow load (roof) (psf);
- (7) the maximum wind load (psf)/speed (mph);
- (8) the seismic zone;
- (9) the occupancy/use group type;
- (10) the construction type; and
- (11) special conditions and/or limitations.
(c) All modular components shall be marked with, or otherwise have permanently affixed, a data plate containing the following information:
- (1) the manufacturer's name, registration number, and address;
- (2) the serial or identification number of the component or components;
- (3) the State insignia number or numbers;
- (4) the name and date of applicable codes;
- (5) the design loads for the component; and
- (6) any special conditions of use for the component.
- (d) The information required in subsection (c) of this section may be placed in the crate in which the component or components are shipped or on a tag attached to the crate or to the component if the component is such that the information may not be marked or permanently affixed to the component.
- (e) Structures designated by the manufacturer as not being designed for placement on a permanent foundation shall have a manufacturer's seal permanently attached inside the door of the electrical panel or near the entrance door if the unit does not have an electrical panel. The seal shall not be smaller than 2 by 1-1/2 inches and shall be constructed of a metallic alloy. The seal must contain the following capitalized statement: THIS STRUCTURE IS NOT DESIGNED FOR PLACEMENT ON A PERMANENT FOUNDATION AND DOES NOT MEET THE REQUIREMENTS OF TEXAS CIVIL STATUTES, ARTICLE 5221f-1, INDUSTRIALIZED HOUSING AND BUILDINGS.
Source Note:The provisions of this §70.71 adopted to be effective April 13, 1990, 15 TexReg 1787; amended to be effective March 16, 1998, 23 TexReg 1305.