- (a) In addition to cost principles and administrative requirements listed in §1.402 in Chapter 1 of this title (relating to Cost Principles and Administrative Requirements), Subrecipients administering DOE programs must also adhere to 10 CFR Part 440, 10 CFR Part 600, and the applicable International Residential Code (IRC).
- (b) WAP Policy Advisory Council. In accordance with Tex. Gov't Code, §2110.005 and 10 CFR §440.17, the Department shall establish the Weatherization Assistance Program Policy Advisory Council (WAP PAC), with which it will consult prior to the submission of the annual plan and award of funds to DOE.
- (c) Adjusted Average Expenditure Per Dwelling Unit. Expenditures of financial assistance provided under DOE-WAP funding for the Weatherization services for labor, weatherization materials, and program support shall not exceed the DOE adjusted average expenditure limit for the current Program Year per Dwelling Unit as provided by DOE, and as cited in the Contract, without special agreement via an approved waiver from the Department.
- (d) Electric Base Load Measures. DOE has approved the inclusion of selected Electric Base Load (EBL) measures as part of the Weatherization of eligible residential units. Refrigerators must be metered for a minimum of two hours when calculating the EBL and SIR.
- (e) Subrecipients may not enter into vehicle lease agreements with WAP funds.
(f) Energy Audit Procedures.
- (1) SIR for the Energy Audit procedures will determine the installation of allowable Weatherization measures. The Weatherization measures must result in energy cost savings over the lifetime of the measure(s), discounted to present value, that equal or exceed the cost of materials, and installation. An Energy Audit may consist of Incidental Repairs, Energy-Saving Measures (starting with Duct Sealing and Infiltration Reduction), and Health and Safety Measures. All Energy-Saving Measures must rank with an SIR of one or greater. The total Cumulative SIR, prior to Health and Safety measures, must be a one or greater in order to weatherize the dwelling unit.
- (2) The Energy Audit has not been approved for multifamily buildings containing 25 or more units. Subrecipients that propose weatherizing a building containing 25 or more units must receive approval from the Department prior to beginning any Weatherization activity.
- (3) Energy Auditors must use the established R-values for existing measures provided in the International Energy Conservation Code (IECC when entering data into the Energy Audit. Subrecipient must follow minimum requirements set in the applicable IRC or jurisdictions authorized by state law to adopt later editions.
- (4) Subrecipients utilizing the Energy Audit must enter into the audit all materials and labor measures proposed to be installed.
Source Note:The provisions of this §6.408 adopted to be effective January 1, 2020, 44 TexReg 8247.