ARSD 20:10:39:56
20 : 10 : 39 : 56 . Analysis of the data collected during the tests. The qualified testing analyst examines the data recorded for the 48 hour test and shall determine the highest steady-state value of cow contact voltage or cow contact current. The qualified testing analyst shall determine the value of primary neutral to reference voltage that was present for the highest cow contact value. These values are identified as cow contact voltage or cow contact current and primary neutral to reference voltage at the time of maximum cow contact voltage or cow contact current. These values are recorded as Vcc48 hr, I cc48 hr, or Vp48 hr. The three data sets created from the values are: