N.Y. Comp. Codes R. & Regs. tit. 1, § 2.45
(a) All indicating and recording thermometers used in connection with the batch pasteurization of milk or milk products shall comply with the applicable specifications set forth in Appendix 3 of this Title. Specifications for test thermometers and other test equipment appear in Appendix 4 of this Title.
(3) Assurance of minimum holding periods. Batch pasteurizers shall be so operated that every particle of milk or milk product will be held at not less than the minimum pasteurization temperature continuously for at least 30 minutes. When milk or milk products are raised to pasteurization temperature in the vat, and cooling is begun in the vat, simultaneously with or before the opening of the outlet valve, the recorder chart shall show at least 30 minutes at not less than minimum pasteurization temperature. When milk or milk products are preheated to pasteurization temperature before entering the vat, the recorder chart shall show a holding period of at least 30 minutes at not less than the minimum pasteurization temperature plus the time of filling from the level of the recorder bulb. When cooling is begun in the holder after the opening of the outlet valve, or is done entirely outside the holder, the chart shall show at least 30 minutes at not less than the minimum pasteurization temperature plus the time of emptying to the level of the recording thermometer bulb. When the recorder time interval on the recorder chart at the pasteurization temperature includes filling and/or emptying time, such intervals shall be indicated on the recorder chart by the operator, by removing the recording thermometer bulb from the milk for a sufficient time to depress the pen, or by turning cold water into the vat jacket at the end of the holding period, or by inscribing the holding time on the chart. The filling time and the emptying time for each holder so operated shall be determined by the commissioner, initially and after any change which may affect these times. No milk shall be added to the holder after the start of the holding period.
(c) Airspace heating.
(3) The temperature shown by the airspace thermometer shall be recorded on the recording thermometer chart each time the pasteurizer is in operation.
(d) Inlet and outlet valves and connections.
The following definitions shall apply to inlet and outlet valves and connections:
(13) Closed-coupled valve shall mean a valve, the seat of which is either flush with the inner wall of the pasteurizer, or so closely coupled that no milk in the valve inlet is more than one degree Fahrenheit (one-half degree Celsius) colder than the milk at the center of the pasteurizer at any time during the holding period. A close-coupled valve which is not truly flush shall be considered as satisfying this requirement when:
(iii) in the case of batch pasteurizers, the outlet and the agitator are so placed as to insure that milk currents will be swept into the outlet.
(e) Design and installation of valves and connections.
All valves and connections shall comply with the following requirements.
(10) All outlet valves shall be kept fully closed during filling, heating and holding periods; and all inlet valves shall be kept fully closed during holding and emptying periods.
(f) Recording charts.
All recording thermometer charts shall comply with the applicable requirements of section 2.48 of this Part (Item 16p[D]).
(b) Time and temperature controls for batch pasteurizers.