Md. Code Regs. 10.15.09.17
Milk Facility Construction and Plan Submission.
Effective May 20, 201946:10 Md. R. 488Health-General Article, §§2-104, 2-105, 21-207, 21-208, 21-210, 21-211, 21-405, 21-406, 21-428, Annotated Code of Maryland
Pursuant to the standards set forth in the Grade “A” Pasteurized Milk Ordinance, Section 12 for construction, reconstruction, or extensive alteration of a milk facility, a person shall submit to the Department:
A. A plan and specifications before:
- (1) Constructing, reconstructing, or extensively altering a milk facility;
- (2) Converting or remodeling an existing building or structure for use as a milk facility;
- (3) Adding, replacing, relocating, or modifying a milk facility process; or
- (4) Adding, modifying, or replacing a clean-in-place (CIP) or other washing system or any part of a clean-in-place or other washing system;
- B. Plans and drawings bearing the name of a professional engineer or a representative of the company performing the work;
C. Contact information for the facility, including:
- (1) The full name, title, and telephone number of each applicant;
- (2) The name of the plant;
- (3) The mailing address;
- (4) The location; and
- (5) Directions to the site;
- D. A narrative describing the scope and purpose of the project, including a projected timeline from start to completion;
- E. An estimate of finished product output per day;
- F. Sample product labels for each product;
G. A list of:
- (1) All products to be produced;
- (2) Raw cream and nonfat, condensed, or any other milk or milk products to be sold; and
- (3) Single service container sources;
H. A scale drawing showing the layout and arrangement of areas within and around the milk facility, including areas for:
- (1) Processing;
- (2) Chemical storage;
- (3) Dry storage;
- (4) Ingredient and product storage;
- (5) Receiving;
- (6) Load out;
- (7) Laboratories;
- (8) Offices;
- (9) Restroom facilities;
- (10) Lockers or a facility for the storage of personal items; and
- (11) Employees to eat and drink beverages;
I. A scale drawing showing the location of all equipment, including:
- (1) Pasteurizers and sterile systems;
- (2) Milk processing equipment;
- (3) Fillers;
- (4) Raw and pasteurized tanks and silos;
- (5) Clean-in-place (CIP) systems;
- (6) Glycol water tanks;
- (7) Recirculating cooling water tanks;
- (8) Boilers;
- (9) Boiler makeup tanks;
- (10) Culinary steam systems; and
- (11) Blow mold systems;
J. A scale drawing showing the location of plumbing and plumbing fixtures, including:
- (1) Water lines;
- (2) Sewer lines;
- (3) Hand sinks;
- (4) Toilets;
- (5) Utility sinks;
- (6) Utensil washing sinks;
- (7) Floor drains;
- (8) Floor sinks;
- (9) Hose stations; and
- (10) All backflow prevention devices;
- K. A legend for each drawing;
L. Specifications for:
(1) Ventilation including, but not limited to, the type and location of:
- (a) An air filter;
- (b) An air pump; and
- (c) A compressor;
- (2) Construction materials for the building and interior finishes; and
- (3) Pasteurizer plate coolers, if separate from the pasteurization system;
- M. A list and description of all boiler, glycol, and recirculating water additives and water treatment;
N. A description of the:
- (1) Type of disposal for wastewater and sewage;
- (2) Source and system for the facility’s potable water supply;
- (3) Lighting fixtures and placement; and
- (4) Recirculating cooling system;
- O. Specification sheets, including manufacturer and model number of all milk facility equipment;
P. A document that lists the flow for all products through the plant, grouped in categories, identifying each functional piece of equipment and each process used in processing and packaging, including:
- (1) Reclamation systems;
- (2) Standardization procedures or formulation procedures, or both;
- (3) Vitamin addition protocol; and
- (4) Draining of product lines;
- Q. Plans, specifications, drawings, and flow diagrams for each high temperature short time (HTST) and higher heat short time (HHST) system, showing each functional component;
- R. Clean-in-place (CIP) flow diagrams from the makeup tanks through all equipment;
- S. If applicable, information and drawings on how separation from product lines will be accomplished;
T. Written step-by-step standard operating procedures (SOPs and SSOPs) for the following, if not included in §W of this regulation:
- (1) Receiving, processing, storing, and packaging of each product;
- (2) Drug residue testing;
- (3) Cleaning and sanitization for all equipment;
- (4) Cleaning and sanitization for the facility; and
- (5) Product trace back, inclusive of production/make sheet;
- U. A pest control program;
- V. Employee training and personal hygiene practices; and
W. A food safety plan that complies with 21 CFR Part 117 and at a minimum includes:
- (1) A written hazard analysis;
(2) Written preventive controls that address:
- (a) Process preventive controls;
- (b) Food allergens;
- (c) Sanitation;
- (d) Supply-chain controls;
- (e) A product recall plan; and
- (f) Other hazards identified in the hazard analysis as requiring a preventive control;
- (3) Written procedures for monitoring the implementation of the preventive controls as appropriate to the nature of the preventative control and its role in the facility’s food safety system;
- (4) Written corrective action procedures as appropriate to the nature of the hazard and the nature of the preventive control; and
- (5) Written verification procedures as appropriate to the nature of the preventative control and its role in the facility’s food safety system.
Authority: Health-General Article, §§2-104, 2-105, 21-207, 21-208, 21-210, 21-211, 21-405, 21-406, 21-428, Annotated Code of Maryland
Effective date: April 10, 1995 (22:7 Md. R. 536)
Regulations .01—.20 repealed and new Regulations .01—.22 adopted effective May 20, 2019 (46:10 Md. R. 488)