Ind. Admin. Code tit. 675, r. 20-3-7
Authority: IC 22-13-2-2
Affected: IC 22-12; IC 22-13; IC 22-15; IC 36-7
Sec. 7. (a) Every spa shall be provided with an approved type circulation system capable of turning over the entire spa water capacity in not less than thirty (30) minutes.
(b) All circulation shall:
(c) A removable strainer or screen shall be installed upstream from all pumps.
(d) Filters shall meet the following requirements:
(e) Air induction systems, when provided, shall:
(f) Chemical feeder systems shall be provided, capable of maintaining a chemical residual and pH level in accordance with 410 IAC, the rules of the Indiana state department of health.
(g) Operation and maintenance instructions, including a laminated pump curve or curves and conversion chart (psi to tdh) shall be provided for circulation system components.
(Fire Prevention and Building Safety Commission; 675 IAC 20-3-7; filed Aug 14, 1989, 9:00 a.m.: 13 IR 61, eff Sep 1, 1989 [IC 4-22-2-36 suspends the effectiveness of a rule document for thirty (30) days after filing with the secretary of state. LSA Document #89-17 was filed Aug 14, 1989.]; readopted filed Sep 11, 2001, 2:49 p.m.: 25 IR 530; filed Nov 25, 2002, 9:00 a.m.: 26 IR 1103; readopted filed Sep 21, 2007, 9:20 a.m.: 20071010-IR-675070388RFA; readopted filed Oct 10, 2007, 9:16 a.m: 20071031-IR-675070388RFA; filed Mar 25, 2011, 10:19 a.m.: 20110420-IR-675090789FRA; readopted filed Aug 7, 2013, 8:51 a.m.: 20130904-IR-675130181RFA; readopted filed Jul 2, 2019, 2:21 p.m.: 20190731-IR-675190264RFA; readopted filed Nov 18, 2025, 10:36 a.m.: 20251210-IR-675240566RFA)