Ind. Admin. Code tit. 410, r. 6-8.3-67
Authority: IC 16-19-3-4
Affected: IC 16-19-3-4; IC 16-41-25
Sec. 67. (a) Piping used in a residential on-site sewage system shall meet or exceed the following applicable standards:
(1) Gravity sewer pipe and gravity effluent sewer pipe shall meet the following standards:
(A) For PVC pipe, the following:
(ii) ASTM D 3034-2021 for
(B) For ABS pipe, the following:
(2) Pressure sewer, effluent force main, manifold, and pressure distribution lateral pipe shall meet the following standards:
(A) For PVC pipe, the following:
(b) Gasketed compression-type joints must be used on pressure sewers when they are located ten (10) feet or less from a water line.
(c) Soil absorption system gravity distribution laterals shall meet one (1) of the following standards:
(d) Gravity distribution laterals shall have two (2) or three (3) rows of holes separated by one hundred twenty (120) degrees with a five-eighths (5/8) inch or three-quarters (3/4) inch hole diameter with holes spaced at five (5) inches or less.
(e) Pipe for subsurface drainage systems shall meet the following standards for polyethylene pipe:
(Indiana Department of Health; 410 IAC 6-8.3-67; filed Oct 19, 2012, 2:06 p.m.: 20121114-IR-410120156FRA; readopted filed Sep 26, 2018, 2:48 p.m.: 20181024-IR-410180328RFA; filed Feb 27, 2024, 10:34 a.m.: 20240327-IR-410220395FRA; readopted filed Nov 14, 2024, 1:24 p.m.: 20241211-IR-410230798RFA)