Ind. Admin. Code tit. 410, r. 16.2-5-1.6
Authority: IC 16-28-1-7
Affected: IC 16-28-2; IC 16-28-5-1
Sec. 1.6. (a) The facility shall make provisions for the handicapped as required by state or federal codes.
(b) The facility shall have adequate plumbing, heating, and ventilating systems as governed by applicable rules of the fire prevention and building safety commission (675 IAC). Plumbing, heating, and ventilating systems shall be maintained in normal operating condition and utilized as necessary to provide comfortable temperatures in all areas.
(c) Each facility shall have an adequate air conditioning system, as governed by applicable rules of the fire prevention and building safety commission (675 IAC). The air conditioning system shall be maintained in normal operating condition and utilized as necessary to provide comfortable temperatures in all resident and public areas.
(d) The facility shall be supplied with safe, potable water, under pressure, from a source approved by the Indiana department of environmental management. If a private water supply is used, the facility shall comply with appropriate laws and rules.
(e) Sewage shall be discharged into a public sewerage system in accordance with the laws and rules of the Indiana water pollution control board, where a system is available. Otherwise, sewage shall be collected, treated, and disposed of in an approved on-site wastewater system in accordance with 410 IAC 6-10.
(f) The facility shall have, for each room used for dining, living, or sleeping purposes, light and ventilation by means of outside windows with an area equal to one-tenth (1/10) of the total floor area of such rooms.
(g) The following standards apply to resident rooms:
(h) The facility shall have natural lighting augmented by artificial illumination, when necessary, to provide light intensity and to avoid glare and reflective surfaces that produce discomfort and as indicated in the following table:
| Minimum Average Area | Foot-Candles |
|---|---|
| Corridors and interior ramp | 15 |
| Stairways and landing | 20 |
| Recreation area | 40 |
| Dining area | 20 |
| Resident care room | 20 |
| Nurses' station | 40 |
| Nurses' desk for charts and records | 60 |
| Medicine cabinet | 75 |
| Utility room | 15 |
| Janitor's closet | 15 |
| Reading and bed lamps | 20 |
| Toilet and bathing facilities | 20 |
| Food preparation surfaces and utensil washing facilities | 70 |
(i) The facility shall house residents only in areas approved by the director for housing and given a fire clearance by the state fire marshal. The facility shall:
(2) Provide each resident the following items upon request at the time of admission:
(A) A bed:
(j) The following standards apply to toilet, lavatory, and tub or showers:
(2) For facilities for which plans were approved prior to April 1, 1997, the following criteria is [sic., are] applicable:
(A) Bathing facilities for residents not served by bathing facilities in their rooms shall be provided as follows:
| Residents | Bathtubs or Showers |
|---|---|
| 3 to 22 | 1 |
| 23 to 37 | 2 |
| 38 to 52 | 3 |
| 53 to 67 | 4 |
| 68 to 82 | 5 |
| 83 to 97 | 6 |
(E) Toilet facilities shall be provided as follows:
| Residents of the Same Sex | Toilets | Open-Front Lavatories |
|---|---|---|
| 3 to 18 | 1 | 1 |
| 19 to 30 | 2 | 2 |
| 31 to 42 | 3 | 3 |
| 43 to 54 | 4 | 4 |
| 55 to 66 | 5 | 5 |
| 67 to 78 | 6 | 6 |
(3) For facilities and additions to facilities for which construction plans are submitted for approval after July 1, 1984, at least one (1) toilet and lavatory shall be provided for each eight (8) residents as follows:
(k) Hot water temperature for all bathing and hand washing facilities shall be controlled by an automatic control valve. Water temperature at point of use must be maintained between one hundred (100) degrees Fahrenheit and one hundred twenty (120) degrees Fahrenheit.
(l) The facility shall have a nourishment station for supplemental food service separate from the resident's unit.
(m) Ice shall be readily available to residents at all times in the facility.
(n) The facility shall have living areas with sufficient space to accommodate the dining, activity, and lounge needs of the residents and to prevent the interference of one (1) function with another as follows:
(1) Dining, lounge, and activity areas shall be:
(o) Each facility shall have an adequate kitchen that complies with 410 IAC 7-24.
(p) The facility shall have a janitor's closet conveniently located on each resident occupied floor of the facility. The janitor's closet shall contain a sink or floor receptacle and storage for cleaning supplies. The door to the janitor's closet shall be equipped with a lock and shall be locked when hazardous materials are stored in the closet.
(q) The facility shall have laundry services either in-house or with a commercial laundry by contract as follows:
(r) For facilities and additions to facilities for which construction plans are submitted for approval after July 1, 1984, if the facility provides therapy, the facility shall have a therapy area.
(s) For purposes of IC 16-28-5-1, a breach of:
(Indiana Department of Health; 410 IAC 16.2-5-1.6; filed Jan 10, 1997, 4:00 p.m.: 20 IR 1571, eff Apr 1, 1997; errata filed Jan 10, 1997, 4:00 p.m.: 20 IR 1593; errata filed Apr 10, 1997, 12:15 p.m.: 20 IR 2415; readopted filed Jul 11, 2001, 2:23 p.m.: 24 IR 4234; filed Jan 21, 2003, 8:34 a.m.: 26 IR 1925, eff Mar 1, 2003; errata filed Jan 21, 2005, 10:32 a.m.: 28 IR 1695; readopted filed May 22, 2007, 1:44 p.m.: 20070613-IR-410070141RFA; readopted filed Sep 11, 2013, 3:19 p.m.: 20131009-IR-410130346RFA; readopted filed Nov 13, 2019, 3:14 p.m.: 20191211-IR-410190391RFA; readopted filed Nov 14, 2025, 11:18 a.m.: 20251210-IR-410240588RFA)