Rule 40-7-1-.32. Physical Facilities: Numbers and Capacities
- (1) Minimum Number. HANDWASHING SINKS shall be provided as specified under 40-7-1-.26(7).
- (2) Handwashing Cleanser, Availability. Each HANDWASHING SINK or group of two (2) adjacent HANDWASHING SINKS shall be provided with a supply of hand cleaning liquid, powder, or bar soap.Pf
(3) Hand Drying Provision. Each HANDWASHING SINK or group of adjacent HANDWASHING SINKS shall be provided with:
- (a) Individual, disposable towels;Pf
- (b) A continuous towel system that supplies the user with a clean towel;Pf or
- (c) A heated-air hand drying device;Pf or
- (d) A hand drying device that employs an air-knife system that delivers high velocity, pressurized air at ambient temperatures.Pf
- (4) Handwashing Aids and Devices, Use Restrictions. A sink used for FOOD preparation or UTENSIL washing, or a service sink or curbed cleaning facility used for the disposal of mop water or similar wastes, may not be provided with the handwashing aids and devices required for a HANDWASHING SINK as specified under 40-7-1-.32(2) and 40-7-1-.32(3) and 40-7-1-.29(7)(c).
- (5) Handwashing Signage. A sign or poster that notifies FOOD EMPLOYEES to wash their hands shall be provided at all HANDWASHING SINKS used by FOOD EMPLOYEES and shall be clearly visible to FOOD EMPLOYEES.
- (6) Disposable Towels, Waste Receptacle. A HANDWASHING SINK or group of adjacent HANDWASHING SINKS that is provided with disposable towels shall be provided with a waste receptacle as specified under 40-7-1-.29(7)(c).
- (7) Minimum Number. Toilets and urinals shall be provided as specified under 40-7-1-.26(8).
- (8) Toilet Tissue, Availability. A supply of toilet tissue shall be available at each toiletPf
(9) Intensity. The light intensity shall be:
- (a) At least 108 lux (10 foot candles) at a distance of 75 cm (30 inches) above the floor, in walk-in refrigeration units and dry FOOD storage areas and in other areas and rooms during periods of cleaning;
(b) At least 215 lux (20 foot candles):
- 1. At a surface where FOOD is provided for CONSUMER self-service such as buffets and salad bars or where fresh produce or PACKAGED FOODS are sold or offered for consumption,
- 2. Inside EQUIPMENT such as reach-in and under-counter refrigerators; and
- 3. At a distance of 75 cm (30 inches) above the floor in areas used for handwashing, WARE WASHING, and EQUIPMENT and UTENSIL storage, and in toilet rooms; and
- (c) At least 540 lux (50 foot candles) at a surface where a FOOD EMPLOYEE is working with FOOD or working with UTENSILS or EQUIPMENT such as knives, slicers, grinders, or saws where EMPLOYEE safety is a factor.
- (10) Mechanical. If necessary to keep rooms free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes, mechanical ventilation of sufficient capacity shall be provided.
(11) Designation.
- (a) Dressing rooms or dressing areas shall be designated if EMPLOYEES routinely change their clothes in the establishment.
- (b) Lockers or other suitable facilities shall be provided for the orderly storage of EMPLOYEES' clothing and other possessions.
- (12) Availability. A service sink or curbed cleaning facility shall be provided as specified under 40-7-1-.26(9)(a).
Authority: O.C.G.A. Secs. 26-2-1 et. seq.
History. Original Rule entitled "Expiration Date of Infant Formula Products" adopted. F. Oct. 28, 1975; eff. Nov. 17, 1975.
Repealed: New Rule entitled "Equipment Functionality" adopted. F. Apr. 30, 1996; eff. May 20, 1996.
Amended: F. Oct. 29, 2003; eff. Nov. 28, 2003, as specified by the Agency.
Amended: F. Aug. 7, 2012; eff. Aug. 27, 2012.
Repealed: New Rule entitled "Physical Facilities: Numbers and Capacities" adopted. F. Sep. 11, 2015; eff. Oct. 1, 2015.