Rule 40-7-1-.19. Equipment, Utensils, and Linens: Location and Installation
(1) Equipment, Clothes Washers and Dryers, and Storage Cabinets, Contamination Prevention.
(a) Except as specified in (b) of this section, EQUIPMENT, a cabinet used for the storage of FOOD, or a cabinet that is used to store cleaned and SANITIZED EQUIPMENT, UTENSILS, laundered LINENS, and SINGLE-SERVICE and SINGLE-USE ARTICLES may not be located:
- 1. In locker rooms;
- 2. In toilet rooms;
- 3. In garbage rooms;
- 4. In mechanical rooms;
- 5. Under sewer lines that are not shielded to intercept potential drips;
- 6. Under leaking water lines including leaking automatic fire sprinkler heads or under lines on which water has condensed;
- 7. Under open stairwells; or
- 8. Under other sources of contamination.
- (b) A storage cabinet used for LINENS or SINGLE-SERVICE or SINGLE-USE ARTICLES may be stored in a locker room.
- (c) If a mechanical clothes washer or dryer is provided, it shall be located so that the washer or dryer is protected from contamination and only where there is no exposed FOOD; clean EQUIPMENT, UTENSILS, and LINENS; and unwrapped SINGLE-SERVICE and SINGLE-USE ARTICLES.
(2) Fixed Equipment, Spacing or Sealing.
(a) EQUIPMENT that is fixed because it is not EASILY MOVABLE shall be installed so that it is:
- 1. Spaced to allow access for cleaning along the sides, behind, and above the EQUIPMENT;
- 2. Spaced from adjoining EQUIPMENT, walls, and ceilings a distance of not more than 1 millimeter or one thirty-second inch; or
- 3. SEALED to adjoining EQUIPMENT or walls, if the EQUIPMENT is exposed to spillage or seepage.
(b) COUNTER-MOUNTED EQUIPMENT that is not EASILY MOVABLE shall be installed to allow cleaning of the EQUIPMENT and areas underneath and around the EQUIPMENT by being:
- 1. SEALED; or
- 2. Elevated on legs as specified under 40-7-1-.19(3)(d).
(3) Fixed Equipment, Elevation or Sealing.
- (a) Except as specified in (b) and (c) of this section, floor-mounted EQUIPMENT that is not EASILY MOVABLE shall be SEALED to the floor or elevated on legs that provide at least a 15 centimeter (6 inch) clearance between the floor and the EQUIPMENT.
- (b) If no part of the floor under the floor-mounted EQUIPMENT is more than 15 centimeters (6 inches) from the point of cleaning access, the clearance space may be only 10 centimeters (4 inches).
- (c) This section does not apply to display shelving units, display refrigeration units, and display freezer units located in the CONSUMER shopping areas of a retail FOOD store, if the floor under the units is maintained clean.
- (d) Except as specified in (e) of this section, COUNTER-MOUNTED EQUIPMENT that is not EASILY MOVABLE shall be elevated on legs that provide at least a 10 centimeter (4 inch) clearance between the table and the EQUIPMENT.
(e) The clearance space between the table and COUNTER-MOUNTED EQUIPMENT may be:
- 1. 7.5 centimeters (3 inches) if the horizontal distance of the table top under the EQUIPMENT is no more than 50 centimeters (20 inches) from the point of access for cleaning; or
- 2. 5 centimeters (2 inches) if the horizontal distance of the table top under the EQUIPMENT is no more than 7.5 centimeters (3 inches) from the point of access for cleaning.
Authority: O.C.G.A. Secs. 26-2-1 et. seq.
History. Original Rule entitled "Food Standards" adopted. F. and eff. June 30, 1965.
Repealed: New Rule entitled "Reheating" adopted. F. Apr. 30, 1996; eff. May 20, 1996.
Amended: F. Oct. 29, 2003; eff. Nov. 28, 2003, as specified by the Agency.
Amended: F. Aug. 7, 2012; eff. Aug. 27, 2012.
Repealed: New Rule entitled "Equipment, Utensils, & Linens: Location and Installation" adopted. F. Sep. 11, 2015; eff. Oct. 1, 2015.