Ga. Comp. R. & Regs. r. 391-3-24-.07
Rule 391-3-24-.07. Lead Clearance Levels
Clearance procedures shall be conducted on all abatement projects by a certified inspector or lead risk assessor after appropriate cleaning has been completed. The following lead clearance levels must be met.
CLEARANCE DUST STANDARDS (Wipe Sampling Only)
Surface/ Medium Level (µg/ft2) (Equal to or less than) Bare and carpeted floors 10 µg/ft2 Interior Window Sills 100 µg/ft2 Window Troughs 400 µg/ft2 Exterior Concrete 800 µg/ft2
Authority: O.C.G.A. § 31-41-1, et seq.
History. Original Rule entitled "Standards for Conducting Lead-Based Paint Activities for Target Housing and Child-Occupied Facilities" adopted. F. June 28, 1996; eff. July 18, 1996.
Repealed: New Rule entitled "Lead Clearance Levels" adopted. F. June 26, 1998; eff. July 16, 1998.
Amended: F. June 27, 2002; eff. July 17, 2002.
Repealed: New Rule of the same title adopted. F. Nov. 19, 2010; eff. Dec. 9, 2010.
Amended: F. Mar. 18, 2022; eff. Apr. 7, 2022.