Fla. Admin. Code R. 62-296.506
(1) Applicability.
(a) The emission limiting standards set forth in Rule 62-296.506, F.A.C., shall apply to application areas, flash-off areas, and ovens of large appliance coating lines involved in prime, single, or topcoat coating operations. Credit for transfer efficiency above the baseline of 60% for spray coating operations can be granted according to the following formula:
X = (te) (z) (y)
____________
Y + (TE) (Z)
where
X = allowable maximum VOC content (kg VOC/liter of coating less
water)
Y = density of the VOC in the maximum VOC content coating
(kg/liter)
Z = applicable emission limit (kg VOC/liter of coating solids
deposited)
TE = transfer efficiency
An EPA and state approved test method for determination of transfer efficiency above the baseline is required.
(3) Control Technology. The emission limit under subsection 62-296.506(2), F.A.C., shall be achieved by:
(4) Test Methods and Procedures. All emissions tests performed pursuant to the requirements of this rule shall comply with the following requirements.
(b) Add-on Control Device.
1. Destructive. The test method for volatile organic compounds shall be EPA Method 25, as described at 40 C.F.R. Part 60, Appendix A-7, adopted and incorporated by reference at Rule 62-204.800, F.A.C., or Attachment 3 of EPA 450/2-78-041, Alternate Test Method for Direct Measurement of Total Gaseous Organic Compounds Using a Flame Ionization Analyzer, adopted and incorporated by reference in Chapter 62-297, F.A.C.
2. Non-destructive. The test method for volatile organic compounds shall be VOC Capture Efficiency Test Procedures as described at Rule 62-297.450, F.A.C. The sampling time for each capture efficiency test run shall be at least 8 hours, unless otherwise approved by the Department pursuant to Rule 62-297.620, F.A.C.
Rulemaking Authority 403.061 FS. Law Implemented 403.021, 403.031, 403.061, 403.087 FS. History–Formerly 17-2.650(1)(f)6., 17-296.506, Amended 11-23-94, 1-1-96, 7-10-14.