Fla. Admin. Code R. 61C-5.006
(1) (a) A registered elevator company shall apply for a permit to install, alter or relocate an elevator by submitting DBPR HR-7015, Application for Permit to Install, Alter or Relocate an Elevator and Certificate of Operation, ( HYPERLINK "https://www.flrules.org/Gateway/reference.asp?No=Ref-09062" https://www.flrules.org/Gateway/reference.asp?No=Ref-09062) incorporated herein by reference and effective 2018 January; and DBPR HR-7023, Affidavit of Elevator Plans Code Compliance, ( HYPERLINK "https://www.flrules.org/Gateway/reference.asp?No=Ref-09063" https://www.flrules.org/Gateway/reference.asp?No=Ref-09063) incorporated herein by reference and effective 2018 January, completed and signed by a certificate of competency holder or certified elevator inspector authorized by the registered elevator company making application. Any remodel, change to or addition of fixtures or components in the elevator cab that requires a test under ASME A17.1, as adopted in Rule 61C-5.001, F.A.C., or meets the definition of an alteration, as defined in Section 399.01(1), F.S., requires an alteration permit. A replacement, as defined in Rule 61C-5.008, F.A.C., does not require an alteration permit.
1. Each application for a permit to install or relocate an elevator must be accompanied by a permit fee of $250 and the certificate of operation fee specified in subsection 61C-5.006(4), F.A.C.
2. Each application for a permit to alter must be accompanied by a permit fee of $200 and a list of the alterations to be performed under the permit.
(c) Every permit issued becomes invalid unless the work authorized by such permit is commenced within 6 months after issuance, or if the work authorized by such permit is suspended or abandoned for a period of 60 days after the time the work is commenced. For good cause, one or more extensions of time may be allowed after the permit holder has commenced work, ordered parts, or started construction on the elevator. Requests for extensions of time must be in writing and must include the circumstances leading to the request and the requested length of the extension. An extension request is not approved until signed by the director of the Division of Hotels and Restaurants or the director’s designee.
1. An extension of time for good cause shall be granted due to delays in construction arising from the non-availability of parts necessary to complete construction; the occurrence of a natural disaster or civil disturbance; the injury, illness, or death of an involved material party to the construction; or other hardship as approved by the director or the director’s designee.
2. Extensions will not be granted when the director or it’s designee determines that the delay is the fault of the contractor or applicant; the delay results from failing to diligently pursue construction; or the necessity for the extension is due to the party’s own negligence and would have been avoided by the party’s exercise of due diligence.
(3) All certificates of operation will expire on July 31 at 11:59 p.m. of each year. Applications and fee payments for renewal of certificates of operation not postmarked or received before August 1 of each year will be deemed delinquent. The following items are required for renewal and must be received by the Bureau of Elevator Safety prior to issuance of a renewal certificate of operation:
| TYPE OF INSTALLATION | CLASS | TYPE OF INSTALLATION | CLASS |
|---|---|---|---|
| Traction Passenger | 01 | Screw Column | 11 |
| Hydraulic Passenger | 02 | Escalator | 12 |
| Traction Freight | 03 | Hand Elevator | 13 |
| Hydraulic Freight | 04 | Sidewalk Elevator | 14 |
| Hand Power Passenger | 05 | Material Lift/Dumbwaiter with Automatic Transfer Device | 15 |
| Hand Power Freight | 06 | Special Purpose Personnel Elevator | 16 |
| Moving Walk | 07 | Inclined Stairway Chairlift | 17 |
| Inclined Lift | 08 | Inclined & Vertical Wheelchair Lift | 18 |
| LU/LA (Limited Use/Limited Application | 09 | Rack and Pinion | 19 |
| Dumbwaiter | 10 |
(8) A certificate of operation holder must submit DBPR Form HR-7016, Elevator Owners Accident Report HYPERLINK "file://BPRTLFP05/DHRShared/DHR%20Rules,%20Reports%20%26%20Amendments/Elevator%20Rules/Rules%20in%20process/61C-5.006%20New%20Accident%20Form/(" \h ( HYPERLINK "https://www.flrules.org/Gateway/reference.asp?No=Ref-15390" https://www.flrules.org/Gateway/reference.asp?No=Ref-15390 HYPERLINK "https://www.flrules.org/Gateway/reference.asp?No=Ref-____" \h ) HYPERLINK "https://www.flrules.org/Gateway/reference.asp?No=Ref-____" \h incorporated herein by reference and effective 2023 February, within 5 working days of any elevator accident as required in Section 399.125, F.S.
An Elevator Owners Accident Report is required to be submitted when the operation of a conveyance results in an accident including, but not limited to, an entrapment or bodily injury.
Rulemaking Authority 399.02, 399.03, 399.07(1), 399.10, 399.125 FS. Law Implemented 399.03, 399.061, 399.07, 399.125, 559.79 FS. History–New 8-21-79, Amended 11-20-79, 10-8-81, 4-21-82, 8-1-82, 11-27-83, 9-19-84, 10-8-85, Formerly 7C-5.06, Amended 10-31-88, 7-1-92, 10-11-92, Formerly 7C-5.006, Amended 2-2-94, 1-1-98, 5-24-01, 9-17-07, 4-21-13, 12-29-14, 4-4-18, 10-29-19, 7-12-23, Technical Change 2-4-26.