D.C. Mun. Regs. tit. 16, § 3306
3306.1.1 Violation of any of the following provisions shall be a Class 1 infraction:
The following abbreviations apply to this section:
IPC- International Plumbing Code
IPMC- International Property Maintenance Code
3306.2.1 Violation of the following provision shall be a Class 1 infraction:
3306.2.2 Violation of the following provisions shall be a Class 2 infraction:
space);
(b) 12F DCMR 1101.2.2 (discharge of water from sump pump directly to adjacent property); or
(c) IPC 802.1-4 (swimming pool water discharge into public/park space).
3306.2.3 Violation of the following provisions shall be a Class 3 infraction:
(a) IPMC 506.2 (obstruction of drains);
(b) IPMC 506.2 (plumbing system not maintained);
(c) 12A DCMR 115.1 (mechanical system not maintained);
(d) 12A DCMR 115.1 (downspout(s) not connected to terminals);
(e) IPMC 506.2 (main sewer line obstructed).
3306.2.4 Violation of the following provisions shall be a Class 4 infraction:
(a) IPMC 505.4 (no hot water at peak demand); or
(b) IPC 604.7 (inadequate water pressure).
3306.3.1 Violation of the following provision shall be a Class 1 infraction:
(a) 12A DCMR 105.1.14 (working without the required electrical permit);
(b) 12A DCMR 105.1.14.1 (exceeding scope of permit);
(c) 12A DCMR § 114A (failure to comply with terms of a Stop Work Order); or
(d) 12A DCMR 114.1 (unauthorized removal of a posted stop work order).
3306.4.1 Violation of the following provisions shall be a Class 1 infraction:
(a) 12A DCMR § 114A (failure to comply with terms of a Stop Work Order);
(b) 12A DCMR 114.1 (unauthorized removal of a posted stop work order);
(c) 12E DCMR M-013.7 (failure to obtain a boiler Certificate of Inspection);
(d) 12E DCMR M-1013.9.1 (violation of conditions of posted Unsafe to Use notice);
(e) 12E DCMR M-1014.2.1 (failure to obtain a boiler installation permit);
(f) 12E DCMR M- 1014.2.1 (no installations permit for boiler and/or unfired pressure vessels);
(g) 17 DCMR 400.2 (operating engineering equipment without proper D.C. engineer's license); or
(h) 12E DCMR M-1013.1.1 (alteration and repair of boilers without required permit).
3306.4.2 Violation of the following provisions shall be a Class 2 infraction:
(a) 12E DCMR M-1014.9.2 (improper location or clearance of a boiler); or
(b) 12E DCMR M-1016.1.2 (welder working without a D.C. certification).
3306.4.3 Violation of the following provision shall be a Class 3 infraction:
12E DCMR M-1013.8 (failure to make a timely repair, alteration, or cleaning, to a boiler specified in a notice of deficiency).
3306.4.4 Violation of the following provisions shall be a Class 4 infraction:
(a) 12E DCMR M-1013.9.1 (improper boiler or pressure vessel operation);
(b) 12E DCMR M-1013.9.1 (certificate of inspection not properly posted); or
(c) 12A DCMR § 109 (denial of entry to boiler room).
The following abbreviations apply to this section:
ASME- American Society of Mechanical Engineers
NFPA- National Fire Protection Association
3306.5.1 Violation of the following provisions shall be a Class 1 infraction:
(a) 12A DCMR § 105A (installation of elevators, escalators, dumbwaiters, man lift(s), and other traveyors without a permit);
(b) 12A DCMR § 114A (failure to comply with terms of a Stop Work Order);
(c) 12A DCMR 114.1 (unauthorized removal of a posted stop
work order).or
(d) 12A DCMR 115.5 (failure to comply with terms of posted Unsafe to Use notice).
3306.5.2 Violation of the following provisions shall be a Class 2 infraction:
(a) ASME A17.1- Rule 1001.1 (Failure to have semi-annual inspections performed);
(b) ASME A17.1- Rule 1002.3 (failure to schedule five year governor speed and safety test);
(c) ASME A17.1- Rule 101.1a and/or 101.3d (failure to provide required fire rated door at elevator machine room with self-closing and self-locking device);
(d) ASME A17.1- Rule 101.a, 101.3d (b) and/or 106.1d 4) (failure to provide a UL listed fire rated self-closing, self-locking, device at machine room door of elevators or pit doors);
(e) ASME A17.1 - Rule 204.7a (failure to provide emergency light and bell operation); or
(f) ASME A17.1 - Appendix 211 (failure to repair emergency phone on elevators).
3306.5.3 Violation of the following provisions shall be a Class 3 infraction:
(a) ASME A17.1- Rule 1206.1h (failure to provide required class fire extinguisher in elevator machine room);
(b) ASME A17.1- Rule 210.1e (3) (failure of elevator to level at floor);
(c) ASME A17.1- Appendix (failure to post fire emergency instruction pictograph adjacent to each non-egress hall push button);
(d) NFPA 70 §620-51(a) (main line disconnects unable to be locked in the off position);
(e) ASME A17.1-Rule 1206.2a (failure to remove all materials not related to the operation from the pit); or
3306.5.4 Violation of the following provisions shall be a Class 4 infraction:
(a) ASME A17.1- Rule 1206.2a (excessive lint and dust in hoist ways);
(b) ASME A17.1- Rule 101.2 (non-related equipment in elevator machine room);
(c) ASME A17.1- 211 (door closure button on elevators in disrepair); or
(d) ASME A 17.1-Rule 1206.2a (unclean elevator pits)
SOURCE: Final Rulemaking published at 52 DCR 4908 (May 27, 2005).