D.C. Mun. Regs. tit. 11-K, § 603
603.1 The maximum permitted building height, not including the penthouse or rooftop structure, as well as the maximum permitted penthouse or rooftop structure height and number of stories, in the StE zones shall be given in the following table:
TABLE K § 603.1: MAXIMUM PERMITTED BUILDING HEIGHT, PENTHOUSE AND ROOFTOP STRUCTURE HEIGHT, AND PENTHOUSE AND ROOFTOP STRUCTURE STORIES
| Zone | Maximum Building Height (ft.) | Maximum Penthouse or Rooftop Structure Height (ft.) | Maximum Penthouse or Rooftop Structure Stories |
|---|---|---|---|
| StE-1 | 25 | 12 ft. except 15 ft. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-2 | Subtitle K § 603.3 | 12 ft. except 18 ft. 6 in. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-3 | |||
| StE-4 | 25 | 12 ft. except 15 ft. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-5 | 65 | 12 ft. except 18 ft. 6 in. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-6 | 90 | 20 ft. | 1 plus mezzanine; Second story permitted for penthouse mechanical space |
| StE-7 | Subtitle K § 603.2 | Subtitle K § 603.2 | Subtitle K § 603.2 |
| StE-8 | 25 | 12 ft. except 15 ft. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-9 | 65 | 12 ft. except 18 ft. 6 in. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-10 | 40 | 12 ft. except 15 ft. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-11 | 25 | 12 ft. except 15 ft. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-12 | 80 | 20 ft. | 1; Second story permitted for penthouse mechanical space |
| StE-13 | 90 | 20 ft. | 1 plus mezzanine; Second story permitted for penthouse mechanical space |
|---|---|---|---|
| StE-14 A & B | 40 | 12 ft. except 15 ft. for penthouse mechanical space | 1; Second story permitted for penthouse mechanical space |
| StE-15 | 80 | 20 ft. | 1; Second story permitted for penthouse mechanical space |
| StE-16 | 90 | 20 ft. | 1 plus mezzanine; Second story permitted for penthouse mechanical space |
| StE-17 | 70 | 20 ft. | 1; Second story permitted for penthouse mechanical space |
| StE-18 | 90 | 20 ft. | 1 plus mezzanine; Second story permitted for penthouse mechanical space |
| StE-19 | 0 | 0 | 0 |
603.2 The maximum permitted building height and penthouse and rooftop structure height within the StE-7 zone is as follows:
603.3 The maximum permitted building height, not including the penthouse or rooftop structure, for any portion of a building shall be as follows based on the building's distance from the property's distance from the property line along Martin Luther King Jr. Avenue:
(b) For a distance of more than two hundred thirty feet (230 ft.) and less than five hundred sixty feet (560 ft.), the maximum permitted building height, not including the penthouse or rooftop structure, shall be eighty feet (80 ft.); and
(c) For a distance of five hundred sixty feet (560 ft.) or more, the maximum permitted building height, not including the penthouse or rooftop structure, shall be ninety feet (90 ft.).
SOURCE: Final Rulemaking published at 63 DCR 2447, 3176 (March 4, 2016 – Part 2); as amended by Final Rulemaking published at 66 DCR 2513 (March 1, 2019); as amended by Final Rulemaking published at 67 DCR 1534 (February 14, 2020); as amended by Final Rulemaking published at 68 DCR 013650 (December 17, 2021); as amended by Final Rulemaking published at 68 DCR 013834 (December 24, 2021).