49 C.F.R. § 192.121
(a) Design pressure. The design pressure for plastic pipe is determined in accordance with either of the following formulas:

P = Design pressure, gage, psi (kPa). S = For thermoplastic pipe, the hydrostatic design basis (HDB) is determined in accordance with the listed specification at a temperature equal to 73 °F (23 °C), 100 °F (38 °C), 120 °F (49 °C), or 140 °F (60 °C). In the absence of an HDB established at the specified temperature, the HDB of a higher temperature may be used in determining a design pressure rating at the specified temperature by arithmetic interpolation using the procedure in Part D.2 of PPI TR-3, (incorporated by reference, see § 192.7). For reinforced thermosetting plastic pipe, 11,000 psig (75,842 kPa). t = Specified wall thickness, inches (mm). D = Specified outside diameter, inches (mm). SDR = Standard dimension ratio, the ratio of the average specified outside diameter to the minimum specified wall thickness, corresponding to a value from a common numbering system that was derived from the American National Standards Institute (ANSI) preferred number series 10. DF = Design Factor, a maximum of 0.32 unless otherwise specified for a particular material in this section
(b) General requirements for plastic pipe and components.
(1) Except as provided in paragraphs (c) through (f) of this section, the design pressure for plastic pipe may not exceed a gauge pressure of 100 psig (689 kPa) for pipe used in:
(2) Plastic pipe may not be used where operating temperatures of the pipe will be:
(c) Polyethylene (PE) pipe requirements.
(1) For PE pipe produced after July 14, 2004, but before January 22, 2019, a design pressure of up to 125 psig may be used, provided:
(2) For PE pipe produced on or after January 22, 2019, a DF of 0.40 may be used in the design formula, provided:
(iv) The wall thickness for a given outside diameter is not less than that listed in Table 1 to this paragraph (c)(2)(iv):
| PE pipe: minimum wall thickness and SDR values | ||
|---|---|---|
| Pipe size (inches) | Minimum wall thickness (inches) | Corresponding dimension ratio (values) |
| 1⁄2″ CTS | 0.090 | 7 |
| 1⁄2″ IPS | 0.090 | 9.3 |
| 3⁄4″ CTS | 0.090 | 9.7 |
| 3⁄4″ IPS | 0.095 | 11 |
| 1″ CTS | 0.099 | 11 |
| 1″ IPS | 0.119 | 11 |
| 1 1⁄4″ CTS | 0.121 | 11 |
| 1 1⁄4″ IPS | 0.151 | 11 |
| 1 1⁄2″ IPS | 0.173 | 11 |
| 2″ | 0.216 | 11 |
| 3″ | 0.259 | 13.5 |
| 4″ | 0.265 | 17 |
| 6″ | 0.315 | 21 |
| 8″ | 0.411 | 21 |
| 10″ | 0.512 | 21 |
| 12″ | 0.607 | 21 |
| 16″ | 0.762 | 21 |
| 18″ | 0.857 | 21 |
| 20″ | 0.952 | 21 |
| 22″ | 1.048 | 21 |
| 24″ | 1.143 | 21 |
(d) Polyamide (PA-11) pipe requirements.
(1) For PA-11 pipe produced after January 23, 2009, but before January 22, 2019, a DF of 0.40 may be used in the design formula, provided:
(2) For PA-11 pipe produced on or after January 22, 2019, a DF of 0.40 may be used in the design formula, provided:
(iv) The minimum wall thickness for a given outside diameter is not less than that listed in table 2 to this paragraph (d)(2)(iv):
| PA-11 pipe: minimum wall thickness and SDRvalues | ||
|---|---|---|
| Pipe size(inches) | Minimum wall thickness(inches) | Corresponding dimension ratio (values) |
| 1⁄2″ CTS | 0.090 | 7.0 |
| 1⁄2″ IPS | 0.090 | 9.3 |
| 3⁄4″ CTS | 0.090 | 9.7 |
| 3⁄4″ IPS | 0.095 | 11 |
| 1″ CTS | 0.099 | 11 |
| 1″ IPS | 0.119 | 11 |
| 1 1⁄4″ CTS | 0.121 | 11 |
| 1 1⁄4″ IPS | 0.151 | 11 |
| 1 1⁄2″ IPS | 0.173 | 11 |
| 2″ IPS | 0.216 | 11 |
| 3″ IPS | 0.259 | 13.5 |
| 4″ IPS | 0.333 | 13.5 |
| 6″ IPS | 0.491 | 13.5 |
(e) Polyamide (PA-12) pipe requirements. For PA-12 pipe produced after January 22, 2019, a DF of 0.40 may be used in the design formula, provided:
(4) The minimum wall thickness for a given outside diameter is not less than that listed in table 3 to this paragraph (e)(4):
| PA-12 Pipe: minimum wall thickness and SDR values | ||
|---|---|---|
| Pipe size(inches) | Minimum wall thickness(inches) | Corresponding dimension ratio (values) |
| 1⁄2″ CTS | 0.090 | 7 |
| 1⁄2″ IPS | 0.090 | 9.3 |
| 3⁄4″ CTS | 0.090 | 9.7 |
| 3⁄4″ IPS | 0.095 | 11 |
| 1″ CTS | 0.099 | 11 |
| 1″ IPS | 0.119 | 11 |
| 1 1⁄4″ CTS | 0.121 | 11 |
| 1 1⁄4″ IPS | 0.151 | 11 |
| 1 1⁄2″ IPS | 0.173 | 11 |
| 2″ IPS | 0.216 | 11 |
| 3″ IPS | 0.259 | 13.5 |
| 4″ IPS | 0.333 | 13.5 |
| 6″ IPS | 0.491 | 13.5 |
(f) Reinforced thermosetting plastic pipe requirements.
(2) The wall thickness for reinforced thermosetting plastic pipe may not be less than that listed in the following table:
| Nominal size in inches(millimeters) | Minimum wallthickness ininches(millimeters) |
|---|---|
| 2 (51) | 0.060 (1.52) |
| 3 (76) | 0.060 (1.52) |
| 4 (102) | 0.070 (1.78) |
| 6 (152) | 0.100 (2.54) |
[Amdt. 192-124, 83 FR 58716, Nov. 20, 2018, as amended at 86 FR 2238, Jan. 11, 2021; Amdt. 192-135, 89 FR 33281, Apr. 29, 2024; Amdt. 192-137, 89 FR 53882, June 28, 2024; Amdt. 192-153, 90 FR 28079, July 1, 2025; Amdt. 192-152, 90 FR 28101, July 1, 2025]