46 C.F.R. § 118.500
(b) Table 1 to § 118.500(b) indicates the minimum required number and type of extinguisher for each space listed. Extinguishers with larger numerical ratings or multiple letter designations may be used if the extinguishers meet the requirements of the table.
| Space | Minimum required rating | Quantity and location |
|---|---|---|
| Operating station | 10-B:C | 1. |
| Machinery space | 40-B:C | 1 in the vicinity of the exit. |
| Open vehicle deck | 40-B | 1 for every 10 vehicles. |
| Accommodation space | 2-A | 1 each for each 2,500 sq ft or fraction thereof. |
| Galley | 40-B:C | 1. |
| Pantry, concession stand | 2-A | 1 in the vicinity of the exit. |
[USCG-2012-0196, 81 FR 48270, July 22, 2016, as amended by USCG-2020-0519, 89 FR 76701, Sept. 18, 2024]