Heating, cooling, and fuel burning appliances and systems in manufactured homes shall be free of defects and shall conform to applicable standards (incorporated by reference, see § 3280.4) in this section unless otherwise specified in this part. When more than one standard is referenced, compliance with any one such standard shall meet the requirements of this part.
(a) Appliances.
- (1) Liquid Fuel-Burning Heating Appliances for Manufactured Homes and Recreational Vehicles—UL 307A.
- (2) Fixed and Location-Dedicated Electric Room Heaters—UL 2021.
- (3) Electric Baseboard Heating Equipment—UL 1042.
- (4) Electric Central Air Heating Equipment—UL 1096.
- (5) Gas-Burning Heating Appliances for Manufactured Homes and Recreational Vehicles—UL 307B.
- (6) Gas Clothes Dryers Volume I, Type 1 Clothes Dryers—ANSI Z21.5.1 (CSA Group).
- (7) Gas-fired Water Heaters, Volume III, Storage Water Heaters with Input Ratings Above 75,000 BTU per Hour, Circulating and Instantaneous—ANSI Z21.10.3 (CSA Group).
- (8) Gas-Fired, Heat Activated Air Conditioning and Heat Pump Appliances—ANSI Z21.40.1 (CSA Group).
- (9) Gas-Fired Central Furnaces (Except Direct Vent Systems)—ANSI Z21.47(CSA Group).
- (10) Connectors for Outdoor Gas Appliances and Manufactured Homes—ANSI Z21.75 (CSA Group).
- (11) Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces—RADCO DS-010.
- (12) Household Cooking Gas Appliances—ANSI Z21.1 (CSA Group).
- (13) Refrigerators Using Gas Fuel—ANSI Z21.19 (CSA Group).
- (14) Gas Water Heaters, Volume I, Storage Water Heaters with Input Ratings of 75,000 BTU per hour or Less—ANSI Z21.10.1 (CSA Group).
- (15) Household Electric Storage Tank Water Heaters—UL 174.
- (16) Household and Similar Electrical Appliances—Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers—UL 60335-2-40.
- (17) Smoke Detectors for Fire Protective Signaling Systems—UL 268.
- (18) Single and Multiple Station Carbon Monoxide Alarms—UL 2034.
- (19) Electric Heating Appliances—UL 499.
(b) Ferrous pipe and fittings.
- (1) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless—ASTM A53/A53M.
- (2) Standard Specification for Electric-Resistance-Welded Coiled Steel Tubing for Gas and Fuel Oil Lines—ASTM A539.
- (3) Pipe Threads, General Purpose (Inch)—ANSI/ASME B1.20.1.
- (4) Welding and Seamless Wrought Steel Pipe—ANSI/ASME B36.10.
(c) Nonferrous pipe, tubing, and fittings.
- (1) Standard Specification for Seamless Copper Water Tube—ASTM B88.
- (2) Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service—ASTM B280.
- (3) Connectors for Gas Appliances—ANSI Z21.24 (CSA Group).
- (4) Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves—ANSI Z21.15 (CSA Group).
- (5) Standard for Gas Supply Connectors for Manufactured Homes—IAPMO TS 9.
- (6) Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube—ASTM B251.
- (7) Standard Specification for Seamless Copper Pipe, Standard Sizes—ASTM B42.
(d) Miscellaneous.
- (1) Factory-Made Air Ducts and Air Connectors—UL 181.
- (2) Closure Systems for use with Rigid Air Ducts and Air Connectors—UL 181A.
- (3) Closure Systems for use with Flexible Air Ducts and Air Connectors—UL 181B.
- (4) Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test—ANSI Z97.1.
- (5) Tube Fittings for Flammable and Combustible Fluids, Refrigeration Service, and Marine Use—UL 109.
- (6) Pigtails and Flexible Hose Connectors for LP-Gas—UL 569.
- (7) Roof Jacks for Manufactured Homes and Recreational Vehicles—UL 311.
- (8) Relief Valves for Hot Water Supply Systems—ANSI Z21.22.
- (9) Automatic electrical controls for household and similar use—Part 2-5: Particular requirements for automatic electrical burner control systems—ANSI Z21.20 (CSA Group).
- (10) Automatic Valves for Gas Appliances—ANSI Z21.21 (CSA Group).
- (11) Gas Appliance Thermostats—ANSI Z21.23 (CSA Group).
- (12) Gas Vents—UL 441.
- (13) Installation of Oil-Burning Equipment—NFPA 31.
- (14) National Fuel Gas Code—NFPA 54/ANSI Z223.1.
- (15) Warm Air Heating and Air Conditioning Systems—NFPA 90B.
- (16) Liquefied Petroleum Gases Code—NFPA 58.
- (17) Flares for Tubing—SAE J533.
- (18) Factory Built Chimneys for Residential Type and Building Heating Appliances—UL 103.
- (19) Factory-Built Fireplaces—UL 127.
- (20) Solid-Fuel Type Room Heaters—UL 1482.
- (21) Fireplace Stoves—UL 737.
- (22) Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment—ANSI/AHRI Standard 210/240 with Addenda 1 and 2.
- (23) Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings—ANSI/ASHRAE 62.2.
- (24) Requirements for Gas Connectors for Connection of Fixed Appliances for Outdoor Installation, Park Trailers, and Manufactured (Mobile) Homes to the Gas Supply—AGA No. 3.
[58 FR 55015, Oct. 25, 1993, as amended at 70 FR 72046, Nov. 30, 2005; 78 FR 73987, Dec. 9, 2013; 89 FR 75753, Sept. 16, 2024]