10 C.F.R. § 431.444
(b) Testing and Calculations. Determine the full-load efficiency of a small electric motor using one of the test methods listed in this paragraphs (b)(1) through (4) of this section.
(1) Incorporation by reference: In § 431.443, DOE incorporated by reference the entire standard for CSA C747-09, CSA C390-10, IEC 60034-1:2010, IEC 60034-2-1:2014, IEC 60051-1:2016, IEEE 112-2017, and IEEE 114-2010 into this section; however, only enumerated provisions of those documents referenced in this section are applicable as follows:
(i) CSA C747-09:
(ii) CSA C390-10:
(iii) IEC 60034-1:2010:
(iv) IEC 60034-2-1:2014:
(v) IEC 60051-1:2016:
(vi) IEEE 112-2017:
(vii) IEEE 114-2010:
(2) Single-phase small electric motors. For single-phase small electric motors, use one of the following methods:
(iii) IEC 60034-2-1:2014 Method 2-1-1A, Section 3 “Terms and definitions”, Section 4 “Symbols and abbreviations”, Section 5 “Basic requirements”, and Section 6.1.2 “Method 2-1-1A—Direct measurement of input and output” (except Section 6.1.2.2, “Test Procedure”). The supply voltage shall be in accordance with section 7.2 of IEC 60034-1:2010 (incorporated by reference, see § 431.443). The measured resistance at the end of the thermal test shall be determined in a similar way to the extrapolation procedure described in section 8.6.2.3.3 of IEC 60034-1:2010, using the shortest possible time instead of the time interval specified in Table 5 therein, and extrapolating to zero. The measuring instruments for electrical quantities shall have the equivalent of an accuracy class of 0,2 in case of a direct test and 0,5 in case of an indirect test in accordance with section 5.2 of IEC 60051-1:2016 (incorporated by reference, see § 431.443).
(A) Additional IEC 60034-2-1:2014 Method 2-1-1A Torque Measurement Instructions.
If using IEC 60034-2-1:2014 Method 2-1-1A to measure motor performance, follow the instructions in paragraph (b)(2)(iii)(B) of this section, instead of section 6.1.2.2 of IEC 60034-2-1:2014;
(3) Polyphase small electric motors of less than or equal to 1 horsepower (0.75 kW). For polyphase small electric motors with 1 horsepower or less, use one of the following methods:
(iii) IEC 60034-2-1:2014 Method 2-1-1A, Section 3 “Terms and definitions”, Section 4 “Symbols and abbreviations”, Section 5 “Basic requirements”, and Section 6.1.2 “Method 2-1-1A—Direct measurement of input and output” (except Section 6.1.2.2, “Test Procedure”). The supply voltage shall be in accordance with section 7.2 of IEC 60034-1:2010. The measured resistance at the end of the thermal test shall be determined in a similar way to the extrapolation procedure described in section 8.6.2.3.3 of IEC 60034-1:2010 using the shortest possible time instead of the time interval specified in Table 5 therein, and extrapolating to zero. The measuring instruments for electrical quantities shall have the equivalent of an accuracy class of 0,2 in case of a direct test and 0,5 in case of an indirect test in accordance with section 5.2 of IEC 60051-1:2016.
(A) Additional IEC 60034-2-1:2014 Method 2-1-1A Torque Measurement Instructions.
If using IEC 60034-2-1:2014 Method 2-1-1A to measure motor performance, follow the instructions in paragraph (b)(3)(iii)(B) of this section, instead of section 6.1.2.2 of IEC 60034-2-1:2014;
(4) Polyphase small electric motors of greater than 1 horsepower (0.75 kW). For polyphase small electric motors exceeding 1 horsepower, use one of the following methods:
[86 FR 23, Jan. 4, 2021]