10 C.F.R. § 429.36
(a) Sampling plan for selection of units for testing.
(2) For each basic model of dehumidifier selected for testing, a sample of sufficient size shall be randomly selected and tested to ensure that—
(i) Any represented value of energy consumption or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(A) The mean of the sample, where:

Or,
(B) The upper 95 percent confidence limit (UCL) of the true mean divided by 1.10, where:

and
(ii) Any represented value of the energy factor, integrated energy factor, or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(A) The mean of the sample, where:

Or,
(B) The lower 95 percent confidence limit (LCL) of the true mean divided by 0.90, where:

(b) Certification reports.
(2) Pursuant to § 429.12(b)(13), a certification report must include the following public product-specific information:
[76 FR 12451, Mar. 7, 2011; 76 FR 24773, May 2, 2011, as amended at 77 FR 65977, Oct. 31, 2012; 80 FR 45824, July 31, 2015; 81 FR 38395, June 13, 2016; 89 FR 82062, Oct. 9, 2024; 90 FR 43380, Sept. 9, 2025]