(a) Sampling plan for selection of units for testing.
(2)
(i) For each basic model of furnaces, other than basic models of those sectional cast-iron boilers (which may be aggregated into groups having identical intermediate sections and combustion chambers) a sample of sufficient size shall be randomly selected and tested to ensure that—
(A) Any represented value of estimated annual operating cost, energy consumption or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(1) The mean of the sample, where:

Or,
(2) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:

and
(B) Any represented value of the annual fuel utilization efficiency or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(1) The mean of the sample, where:

Or,
(2) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

(ii) For the lowest capacity basic model of a group of basic models of those sectional cast-iron boilers having identical intermediate sections and combustion chambers, a sample of sufficient size shall be randomly selected and tested to ensure that—
(A) Any represented value of estimated annual operating cost, energy consumption or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(1) The mean of the sample, where:

Or,
(2) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:

and
(B) Any represented value of the fuel utilization efficiency or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(1) The mean of the sample, where:

Or,
(2) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

(iii) For the highest capacity basic model of a group of basic models of those sectional cast-iron boilers having identical intermediate sections and combustion chambers, a sample of sufficient size shall be randomly selected and tested to ensure that—
(A) Any represented value of estimated annual operating cost, energy consumption or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(1) The mean of the sample, where:

Or,
(2) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:

and
(B) Any represented value of the fuel utilization efficiency or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(1) The mean of the sample, where:

Or,
(2) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

(iv) For each basic model or capacity other than the highest or lowest of the group of basic models of sectional cast-iron boilers having identical intermediate sections and combustion chambers, represented values of measures of energy consumption shall be determined by either—
(B) Testing a sample of sufficient size to ensure that:
(1) Any represented value of estimated annual operating cost, energy consumption or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(i) The mean of the sample, where:

Or,
(ii) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:

and
(2) Any represented value of the energy factor or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(i) The mean of the sample, where:

Or,
(ii) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

(b) Certification reports.
(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information:
(3) Pursuant to § 429.12(b)(13), a certification report shall include the following additional product-specific information:
Note 1 to § 429.18: Prior to February 17, 2023, certification reports must be submitted as required either in this section or 10 CFR 429.18 as it appears in the 10 CFR parts 200 through 499 edition revised as of January 1, 2022. On or after February 17, 2023, certification reports must be submitted as required in this section.
[76 FR 12451, Mar. 7, 2011; 76 FR 24765, May 2, 2011, as amended at 76 FR 38292, June 30, 2011; 81 FR 2646, Jan. 15, 2016; 87 FR 43977, July 22, 2022]