VANESSA G. CHAPMAN, as Special Personal Representative of the ESTATE OF KYLE E. CHAPMAN, JR., deceased, Plaintiff-Appellee, v. MAYTAG CORPORATION, Defendant-Appellant.
No. 01-4061
United States Court of Appeals For the Seventh Circuit
ARGUED MAY 21, 2002—DECIDED JULY 29, 2002
Appeal from the United States District Court for the Southern District of Indiana, Indianapolis Division. No. 99 C 39—Kennard P. Foster, Magistrate Judge.
BAUER, Circuit Judge. Vanessa Chapman filed a wrongful death suit against Maytag Corporation on behalf of the estate of her late husband, Kyle Chapman. Mr. Chapman was electrocuted when he touched a metal surface energized by a current emanating from a Maytag range in the Chapman’s home. The case was tried to a jury, which returned a verdict and substantial damages in favor of the Chapmans. Maytag appeals the verdict arguing, among other things, that the district court erroneously admitted the testimony of the Chapman’s expert without satisfying the mandates of
BACKGROUND
On January 2, 1997, Kyle and Vanessa Chapman purchased a Magic Chef range manufactured by Maytag Corporation. With the range, the Chapmans received an Owner’s Guide, a Gas Installation Manual and a warning label, affixed to the range’s power cord. All three documents specifically advised the consumer that the range must be plugged into a properly grounded three-hole receptacle in compliance with local rules and the National Electrical Code, and that failure to do so may result in shock hazard. Nevertheless, Mr. Chapman plugged the range into a kitchen outlet that he previously installed himself as part of some remodeling to their home. This outlet had a three-hole, grounding type receptacle but Mr. Chapman did not install it correctly: he failed to install a grounding wire and, contrary to the explicit Maytag warnings, the outlet was not grounded.
The Maytag range was manufactured in 1996 at Maytag’s Magic Chef factory in Cleveland, Tennessee. The parties do not dispute that the range was defective when it left the Maytag factory. When it was assembled, a wire branching off the power cord that is designed and intended to be enclosed within a metal housing on the rear of the unit instead became pinched between the metal frame of the range and the back cover plate that covered the electrical wiring. Over time, the insulation on the pinched wire wore down and increasing amounts of electrical current ran into the stove housing, on to the gas line, into the wall, and eventually to the heating ducts.
On several occasions in late July and early August of 1998, the Chapmans experienced electrical shocks from cur
Mrs. Chapman filed a wrongful death suit against Maytag on behalf of her husband’s estate. The suit alleged that the Maytag range was defective and that the defect was the cause of Mr. Chapman’s death. It is undisputed that over time, the insulation covering the pinched wire had broken down and caused a short circuit, allowing electricity to flow from the pinched wire and ultimately to the ductwork. The parties disagree on the nature of the short circuit. Maytag argues that the defect in the range was not the source of the accident and that Mr. Chapman’s death could have been avoided had he plugged the range into a properly grounded outlet, as directed. Mrs. Chapman insists that the accident would have occurred regardless of whether or not the outlet was grounded.
On January 13, 2000, Maytag moved for summary judgment, proffering the affidavit of its expert, Dr. Andrew Neuhalfen, who holds a Ph.D. in Materials Engineering and a B.S. in Electrical Engineering. Dr. Neuhalfen testified that prior to Mr. Chapman’s accident, there was a complete, instantaneous breakdown of the insulation covering the pinched wire. Had the outlet been properly grounded, the current flowing into the frame of the range would have been sufficient to trip the circuit breaker instantaneously, thus terminating the electric current to the outlet to which the stove was connected. According to Dr. Neuhalfen, this would have happened some time prior to the time that Mr. Chapman came into contact with the metal ductwork in the crawl space. Dr. Neuhalfen, there
In response to Maytag’s summary judgment motion, Mrs. Chapman proffered an affidavit of her own expert, James Petry, who holds an undergraduate degree in Mechanical Engineering. Petry put forth an alternative theory as to why the circuit breaker failed to trip at the time of the accident: a “resistive short” theory; that is, the short circuit created by the pinched wire was a resistive short, rather than a direct short. Petry opined that vibrations in the floor of the Chapman’s kitchen caused the insulation covering the pinched wire to wear through and as a result, current escaped from the circuit and passed through the insulation, into the range chassis, then through the gas line to the furnace and eventually to the heating ducts. Petry stated that this leaked current eventually became high enough to electrocute Mr. Chapman, but was not high enough to trip the circuit breaker in the electrical panel of the house. Based on this “resistive short” theory, Petry asserted that the accident would have occurred regardless of whether the outlet was properly grounded. Petry represented to the court that he was “currently designing a testing procedure which when completed will conclusively prove this theory to be true.”
Maytag filed a reply and a motion in limine to bar Petry’s testimony as an expert, arguing that Mrs. Chapman failed to satisfy the requirements for expert testimony pursuant to
At trial, Maytag renewed its objection to Petry’s testimony as an expert, but the objection was overruled. After the jury returned a verdict in favor of the Chapmans, Maytag moved for a new trial, again arguing that Petry’s “resistive short” theory should have been excluded pursuant to
ANALYSIS
A. Expert Testimony
Maytag first argues that the district court erroneously admitted Petry’s testimony because none of the requisite reliability criteria for the admission of scientific expert testimony was satisfied. Matters relating to the admissibility of scientific expert testimony are governed by
Under Daubert, the district court is to perform a gatekeeping function and conduct a two-step analysis be
Maytag contends that Petry’s testimony did not meet the first prong of the Daubert test. Petry concluded that the insulation enclosing the pinched wire eventually became compromised, allowing a fatal amount of electrical current to “leak through” the insulation of a 120 volt wire without tripping a 20-amp circuit breaker. He further hypothesized that this leakage occurred for weeks prior to the accident, without completely destroying the insulation or causing a direct short. Consequently, according to Petry, the grounding of the receptacle would not have prevented the electrocution. In response, Maytag argued that Petry was not qualified to offer such an opinion about electricity because: he does not have sufficient knowledge or experience in the field, he has no graduate training in electrical engineering, he does not attend education classes or seminars regarding electrical engineering, he has never published or lectured in the field of electrical science or engineering, and he has never previously testified as an expert on electrical issues. Maytag further ar
We agree with Maytag that the district court failed to properly assess whether Petry’s theory is scientifically valid. The purpose of the Daubert standard is to ensure that any admitted scientific evidence is reliable; that is, well-grounded in methods and procedures of science. Bourelle v. Crown Equip. Corp., 220 F.3d 532, 536 (7th Cir. 2000). The focus of the district court’s Daubert inquiry must be solely on principles and methodology, not on the conclusions they generate. Cummins v. Lyle Indus., 93 F.3d 362, 368 (7th Cir. 1996). Daubert sets forth a nonexclusive list of factors or guideposts that a court should consider for this analysis: (1) whether the theory can be and has been verified by the scientific method through testing; (2) whether the theory has been subjected to peer review; (3) the known or potential rate of error; and (4) the general acceptance of the theory in the scientific community. Id. It is incumbent upon the trial court to carefully consider these factors before admitting any expert scientific evidence. The Daubert test is a flexible one and there is no requirement that an expert’s testimony satisfy each of the listed factors. United States v. Vitek Supply Corp., 144 F.3d 476, 485 (7th Cir. 1998). However, the record in this case reveals that the district court conducted virtually no Daubert analysis of Petry’s qualifications in light of these factors.
A very significant Daubert factor is whether the proffered scientific theory has been subjected to the scientific
Further, Petry’s testimony failed to satisfy any of the other Daubert guideposts for reliability. Petry presented no proof that his theory is generally accepted in the scientific community. Cummins, 93 F.3d at 369 (noting that Daubert suggests the review of experimental, statistical, or other scientific data generated by others in the field). Instead, his theory is novel and unsupported by any article, text, study, scientific literature or scientific data produced by others in his field. Id. (excluding an expert’s scientific opinion where expert failed to “read any studies, surveys or analyses” in support of his theory). Additionally, by his own admission, Petry has not published any writings or studies concerning his “resistive short” theory. Unsubstantiated testimony, such as this, does not ensure that “the experts‘s opinion has a reliable basis in knowledge and experience of his discipline.” Deimer v. Cincinnati Sub-Zero Prods, Inc., 58 F.3d 341, 345 (7th Cir. 1995). The Daubert standard and
Petry’s “resistive short” theory was relevant to Maytag’s contention that the electrocution would not have occurred if the outlet was grounded, and therefore, to the ultimate issue of the parties’ comparative faults. The jury returned only a general verdict, so it cannot be determined whether the jury relied on Petry’s testimony in apportioning fault. Because we find that Petry’s testimony was improperly admitted, a new trial is required.
B. Pretrial Order
Maytag also argues that the district court’s rulings in Pretrial Order No. 2 were erroneous. The pretrial ruling states that: (1) adequate warnings cannot render a product with a manufacturing defect non-defective under Indiana law, even if compliance with the warnings would have rendered the product safe; (2) misuse is not a complete defense to a strict liability claim, but rather a factor going to the issue of comparative fault under
We find that the district court’s pretrial order is not contrary to Indiana law. First, Maytag’s warnings have no bearing on the defective condition of the range. It is undisputed that Maytag’s range was manufactured with a defect. We believe that the district court correctly determined that “adequate warnings will not render a product with a manufacturing defect non-defective,” regardless of whether compliance with the warnings would have rendered the product safe. Although Maytag provided numerous warnings with which Mr. Chapman failed to comply, “warnings cannot make a dangerous product safe.” Marshall v. Clark Equip. Co., 680 N.E.2d 1102, 1105 (Ind. App. 1997). Accordingly, it was well within the discretion of the district court to hold that warnings will save a product from being defective only when a product is without manufacturing defects. See, e.g., Glover v. BIC Corp., 6 F.3d 1318, 1323 (9th Cir. 1993) (holding that “[a]lthough an adequate warning will prevent the reliance on a theory of strict liability in a failure to warn defect case, such a warning will not make safe a product with a manufacturing defect“).
Second, the district court did not err when it determined that the defense of misuse is not a complete defense, but instead is an element of comparative fault. The court’s order cites the amendment to the Indiana products liability statute, which states: “The fault of the person suffering the physical harm . . . shall be compared by the trier of fact in accordance with [sections of the comparative fault act].” The Indiana General Assembly defined “fault” as “an act of omission that is negligent, willful, wanton, reckless or intentional toward the person or property of others.”
Finally, Maytag challenges the district court’s determination that Mr. Chapman’s failure to heed the warnings is not “misuse” under Indiana law. In support of its position, Maytag cites only Indiana cases in which the defendant was injured by a defect-free product. We agree with the district court that the Chapmans’ case is extraordinary and, therefore, distinguishable, based on the undisputed fact that the Maytag range was defective. The court reasoned that “an Indiana court would interpret the statute and make the policy decision to not allow Maytag to assert the defense of misuse on the basis of Mr. Chapman’s failure to comply with its warnings.” Again, we find that this conclusion was within the sound discretion of the district court.
CONCLUSION
For the foregoing reasons, we REVERSE and REMAND this matter to the district court for a new trial.
A true Copy:
Teste:
Clerk of the United States Court of Appeals for the Seventh Circuit
USCA-97-C-006—7-29-02