(2) A portable oxygen unit shall be carried. It shall be located near a patient compartment door and shall be accessible from outside of the ambulance. The portable oxygen unit shall have at least a 13-cubic-foot container and shall be equipped with a yoke, a pressure gauge, a non-gravity-dependent flowmeter, a delivery tube and oxygen masks. The portable oxygen supply shall have a minimum 500 PSI. The unit shall be capable of delivering an oxygen flow of at least 15 liters per minute. Portable cylinders or kits located in the patient compartment shall be secured with quick-release securing fittings. A full spare cylinder shall be stored in the ambulance. Oxygen masks shall be transparent and disposable.
Note: Pursuant to s. Trans 309.25, this section is repealed upon promulgation by the department of health services of administrative rules establishing standards and inspections, as well as legislative appropriation of resources for such inspections.
History: CR 19-074: r. and recr. Register October 2020 No. 778, eff. 11-1-20; correction in (1) made under s. 35.17, Stats., Register October 2020 No. 778.