- (1) The first step at the service door shall be not more than 18 inches above the ground when the vehicle is empty. The use of a portable step may not be considered in meeting this requirement.
- (2) The riser of the upper step at the service door shall be not more than 15 inches.
- (3) A grab handle not less than 10 inches in length shall be provided in an unobstructed location inside doorway to assist a person entering or leaving a HSV.
- (4) The surface of the steps shall be of nonskid material or construction.
History
History: Cr. Register, March, 1982, No. 315, eff. 4-1-82; am. (1), Register, April, 1997, No. 496, eff. 5-1-97.