Wis. Admin. Code § PSC 185.65
(1) The test flow limits for positive displacement, compound, and turbine meters shall be as follows:
Note: See AWWA Standards C-700 (Positive Displacement Meters), C-702 (Compound Meters), and C-701 (Turbine Meters).
Note: * See s. PSC 185.61 (1).
(2) Positive displacement meters shall have a percent registration between 98.5 and 101.5 within the range of normal test flow limits before being placed in service. In addition, new meters shall have a percent registration at the minimum test flow between 90 [95] and 101.5. In all other cases, the percent registration shall be between 90 and 101.5 before being placed in service. These requirements, in addition to flow, are shown in the table below.
Note: It is the intent of the commission that new meters have an accuracy limits percent between 95 and 101.5.
* Section PSC 185.73 (3) provides that at this flow rate the test quantity may be reduced to that equivalent to one-half revolution of the test dial. For the typical 5/8-inch meter the minimum test quantity would, therefore, be 5 gal. or 1/2 cu. ft.
History: Cr. Register, January, 1997, No. 493, eff. 2-1-97.