Rescue equipment shall meet all of the following:
(1) Required equipment.
(a) Good repair and accessible.
- 1. All rescue equipment shall be maintained in good repair. P
- 2. Rescue equipment shall be mounted or positioned in a conspicuous place and shall be readily accessible. Pf
(b) Shepherd’s crook, ring buoy, and rescue tube.
1.
- a. For each basin of water over 10 feet in length and over 2 feet deep, an intact shepherd’s crook-type pole shall be provided. P
- b. For non-guarded pools, the shepherd’s crook shall be long enough to effect a rescue in the deepest part of the pool. P
- c. If the shepherd’s crook is not one continuous pole, the pieces shall be securely connected with durable nuts and bolts or similar hardware. P
2. For each lifeguard chair, or for a pool 30 feet or more in width that does not have lifeguard chairs, at least one of the following shall be provided:
- a. A ring buoy having a minimum outside diameter of 20 inches. Each ring buoy shall be attached to a 1/4 inch rope having a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less. P
- b. A rescue tube. P
(c) Safety rope.
- 1. If applicable, a safety rope shall be provided pursuant to s. SPS 390.18 (1). Pf
- 2. The safety rope shall remain in place except during a lifeguarded activity or adult-only lap swim. Pf
- 3. The safety rope and floats shall be maintained in good repair and working order. Pf
- (d) Spine board. A spine board with straps and head immobilizer in good condition shall be available at a pool where a lifeguard is required pursuant to s. ATCP 76.23. P
(2) Telephone.
- (a) Connection to emergency services. A telephone capable of connecting with 911 or emergency dispatch services is accessible at all times during pool operation. P
(b) Other technologies. Telecommunication technology, other than a landline telephone, may be used if, in the pool area, the telecommunication device is equipped with all of the following:
- 1. A permanent continuous power supply with battery backup.
- 2. A reliable service connection. P
- (c) Location. The location of the telephone shall be within 25 feet of the pool area. P
- (d) Emergency numbers and address. A current list of emergency telephone numbers and the facility’s location shall be attached to or posted near the telephone. Pf
History
History: CR 22-021: cr. Register June 2023 No. 810, eff. 9-24-23.