(1) Renovator responsibilities. Certified renovators are responsible for ensuring compliance under WAC 365-230-330 at all renovations to which they are assigned. A certified renovator:
- (a) Must perform all of the tasks described under WAC 365-230-330(2) and must either perform or direct workers who perform all of the tasks described under WAC 365-230-330(1).
- (b) Must provide training to workers on the work practices required by WAC 365-230-330(1).
- (c) Must be physically present at the worksite when signs required by WAC 365-230-330 (1)(a) are posted, while the work area containment required by WAC 365-230-330 (1)(b) is being established, and while the work area cleaning required by WAC 365-230-330 (1)(e) is performed.
- (d) Must regularly direct work being performed by other individuals to ensure that the work practices required by WAC 365-230-330(1) are being followed, including maintaining the integrity of the containment barriers and ensuring that dust or debris does not spread beyond the work area.
- (e) Must be available, either on-site or by telephone, at all times that renovations are being conducted.
- (f) When requested by the party contracting for renovation services, must use an acceptable test kit to determine whether components to be affected by the renovation contain lead-based paint.
- (g) Must have with them at the worksite copies of their initial course completion certificate and their most recent refresher course completion certificate.
- (h) Must prepare the records required by WAC 365-230-340 (2)(a)(ii) and (f).
(2) Dust sampling technician responsibilities. When performing optional dust clearance sampling under WAC 365-230-330, a certified dust sampling technician:
- (a) Must collect dust samples in accordance with WAC 365-230-200 (8)(f)(i) through (iv), must send the collected samples to a laboratory recognized under TSCA section 405(b) (National Lead Laboratory Accreditation Program (NLLAP)) as found under WAC 365-230-200 (7)(h), and must compare the results to the clearance levels in dust less than 40 µg/ft2 on floors, less than 250 µg/ft2 on windowsills, and less than 400 µg/ft2 on troughs.
- (b) Must have with them at the worksite copies of their initial course completion certificate and their most recent refresher course completion certificate.
[Statutory Authority: RCW 70.103.030. WSR 14-03-104, § 365-230-385, filed 1/20/14, effective 2/20/14. Statutory Authority: RCW 70.103.10 [70.103.010], 70.103.20 [70.103.020], 70.103.30 [70.103.030], 70.103.40 [70.103.040], 70.103.50 [70.103.050], 70.10.80 [70.103.080], and 70.103.90 [70.103.090]. WSR 11-07-067, § 365-230-385, filed 3/21/11, effective 4/21/11.]