Wash. Admin. Code § 296-96-24670
(1) Escape ladders shall be installed and shall extend the full length of the hoistway.
(a) Ladders shall be installed in a manner to provide access to an emergency exit and shall be located in a position so that in an emergency a person can safely transfer from the car platform to the ladder.
| Note: | Transfer is considered safe when a person can maintain 3 points of contact while making the transfer. |
(4) Adequate lighting shall be installed and operating in the path of travel.
| Note: | For the purpose of this section, adequate lighting shall be 5 fc. |
[Statutory Authority: RCW 70.87.030. WSR 23-17-141, § 296-96-24670, filed 8/22/23, effective 10/2/23. Statutory Authority: Chapter 70.87 RCW. WSR 21-18-096, § 296-96-24670, filed 8/31/21, effective 10/1/21; WSR 18-18-070, § 296-96-24670, filed 8/31/18, effective 10/1/18.]