Wash. Admin. Code § 296-96-24660
(1) Hoisting ropes shall be of good grade traction elevator wire rope and shall:
(2) Cable fastenings shall be by babbitted tapered elevator sockets or other acceptable methods approved by the department. If cable clamps are used, a minimum of 3 cable clamps shall be provided. U-shaped clamps shall not be acceptable.
Where passed around a metal or other object less than 3 times the diameter of the cable, a thimble of the correct size shall be inserted in the eye.
[Statutory Authority: RCW 70.87.030. WSR 23-17-141, § 296-96-24660, filed 8/22/23, effective 10/2/23. Statutory Authority: Chapter 70.87 RCW. WSR 18-18-070, § 296-96-24660, filed 8/31/18, effective 10/1/18.]