(1) Inclined conveyance elevator frames and platforms shall:
- (a) Be built of metal, a combination of metal and wood or other materials of equal strength;
- (b) Have a safety factor of at least 5; and
- (c) Be suitably prepared and/or protected from exposure to weather.
(2) Inclined conveyance chassis shall:
- (a) Be built of metal, except for the guiding members;
- (b) Have a safety factor of at least 5, based upon the conveyance's rated load; and
- (c) Have the chassis guiding members retained and/or enclosed in guides so that the chassis cannot be derailed.
- (3) Cast iron may not be used in the construction of the conveyance frame or chassis.
- (4) A car shall have only one compartment.
[Statutory Authority: Chapter 70.87 RCW. WSR 18-18-070, § 296-96-24234, filed 8/31/18, effective 10/1/18.]