(1) You must make sure each ladder is able to support, without failure, the total of the following loads:
- (a) At least two loads of two hundred and fifty pounds each, concentrated between any two consecutive attachments.
- (b) Any additional concentrated loads of two hundred and fifty pounds each determined from the anticipated use of the ladder.
(c) Anticipated loads caused by all of the following that apply:
- (i) Ice buildup.
- (ii) Winds.
- (iii) Rigging attached to the ladder, including the load to be lifted.
- (iv) Impact loads resulting from the use of ladder safety devices.
(2) You must make sure the design of rails, supports, and fastenings includes:
- (a) Live loads to be supported by the ladder; and
- (b) The weight of the ladder and everything attached to it.
- (3) You must consider all live loads to be concentrated at the point or points that will cause the maximum stress on the ladder or structural member.
- (4) You must make sure each step or rung is capable of supporting a single concentrated load of at least two hundred fifty pounds applied in the middle of the step or rung.
- (5) You must make sure the design stresses for wood components of ladders meet the requirements and specifications of ANSI A14.1, American National Standard for Ladders-Portable Wood-Safety Requirements, in effect when the ladder was installed.
- (6) You must make sure fastenings are designed to meet the ladder load requirements.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060, and chapter 49.17 RCW. WSR 14-09-095, § 296-876-60010, filed 4/22/14, effective 7/1/14. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 06-16-020, § 296-876-60010, filed 7/24/06, effective 12/1/06.]