(1) You must make sure brackets are all of the following:
- (a) Secured in place by at least one wire rope that's at least one-half inch (1.27 cm) in diameter;
- (b) Attached to the securing wire rope by a positive locking device, or equivalent, that will prevent the bracket from being unintentionally detached from the rope;
(c) Provided with a shoe, heel block, foot, or a combination that:
- (i) Is located at the contact point between the supporting structure and the bottom of the bracket; and
- (ii) Will prevent lateral movement of the bracket.
(2) You must secure the platforms to the brackets in a way that prevents:
- (a) The platforms from separating from the brackets; and
- (b) The platforms or brackets from moving on a completed scaffold.
(3) You must make sure wire rope placed around the structure to provide a safe anchorage for personal fall arrest systems used by employees erecting or dismantling scaffolds:
- (a) Is at least five-sixteenths inch (0.8 cm) in diameter;
- (b) Provides an anchorage that meets the requirements of WAC 296-874-20058;
- (c) For construction activities, go to Part C-1, in the safety standards for construction work, chapter 296-155 WAC.
(4) You must make sure each wire rope used for securing brackets in place or as an anchorage for personal fall arrest systems is all of the following:
- (a) Protected from damage due to contact with edges, corners, protrusions, or other parts of the supporting structure or scaffold components;
(b) Tensioned by a turnbuckle or equivalent means. Turnbuckles must be:
- (i) At least one inch (2.54 cm) in diameter; and
- (ii) Connected to the other end of its rope by an eye splice thimble that's sized appropriate to the turnbuckle.
- (c) Not used with U-bolt wire rope clips.
- (5) You must make sure materials are not dropped to the outside of the supporting structure.
- (6) You must erect the scaffold by progressing around the structure in only one direction.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-874-40034, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and 29 C.F.R. 1926, Subpart M, Fall Protection. WSR 13-04-073, § 296-874-40034, filed 2/4/13, effective 4/1/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 05-01-054, § 296-874-40034, filed 12/7/04, effective 3/1/05.]