Wash. Admin. Code § 296-874-30002
(1) You must meet the following strength requirements:
(2) Surfaces that support scaffold support devices must withstand four times the rated load of the hoist.
| Note: | Scaffold support devices include outrigger beams, cornice hooks, parapet clamps, and similar devices. |
Table 4
Suspended Scaffold Strength Requirements
| These scaffold components: | Must meet these strength requirements: |
| Adjustable scaffoldSuspension ropes, including connecting hardware | Support six times the rated load of the hoist. |
| Adjustable scaffoldDirect connections to roofs and floorsCounterweights used to balance the scaffold | Resist four times the tipping moment with the scaffold operating at the rated load of the hoist. |
| Nonadjustable scaffoldSuspension ropes, including connecting hardware | Support six times the maximum intended load applied or transmitted to the rope. |
| All other scaffold components | Support its own weight plus four times the maximum intended load. |