Important:
In addition to these requirements, you also need to meet the requirements of both of the following sections in this chapter:
1. Suspended working platforms and manned platforms used on supported equipment, WAC 296-870-70050;
2. Working platform fall protection, WAC 296-870-70055.
(1) You must make sure each stabilizer tie is equipped with a "quick connect - quick disconnect" device for attachment to the building anchor that:
- (a) Cannot be accidentally disengaged; and
- (b) Is resistant to adverse environmental conditions.
- (2) You must make sure the platform has a stopping device that will interrupt the hoist power supply in the event the platform contacts a stabilizer tie during its ascent.
(3) You must make sure intermittently stabilized platforms use stabilizer ties that:
- (a) Allow the specific attachment length needed to obtain the predetermined angulation of the suspended wire rope; and
- (b) Maintain the specific attachment length at all building anchor locations.
- (4) You must make sure stabilizer ties can be attached and removed without horizontal movement of the platform.
(5) You must make sure platform-mounted equipment and suspension wire ropes:
- (a) Will not be damaged by the loads from the stabilizer tie or its building anchor; and
- (b) Are able to withstand a load that is at least twice the ultimate strength of the stabilizer tie.
- (6) You must make sure building face rollers are placed so they do not contact exterior anchors used on the building face.
- (7) You must make sure the platform maintains continuous contact with the building face while ascending and descending.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-870-70070, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 47.17.060. WSR 06-19-075, § 296-870-70070, filed 9/19/06, effective 1/1/07.]