Wash. Admin. Code § 296-842-20010
(1) Use SCBA and air-line respirators safely:
DO NOT supply compressed oxygen to SCBAs or air-line respirators that previously used compressed air.
| Note: | Compressed air leaves residues containing hydrocarbons such as oil or grease. Fire or explosion can occur if compressed oxygen makes contact with these residues. |
(4) Use equipment specifically designed for oxygen service or distribution IF oxygen concentrations greater than 23.5% are used.
| Note: | Respiratory equipment NOT designed for oxygen service or distribution can create fire or explosion hazards in oxygen concentrations higher than 23.5%. |
(5) Make sure cylinders used to supply breathing air for SCBAs or air-line respirators are tested and maintained as described in the federal Department of Transportation's (DOT) Shipping Container Specification Regulations, Title 49 C.F.R. Part 180.
| Note: | 1. Use only cylinders marked (with serial number, cylinder pressure, DOT exemption number, and test dates) according to these DOT regulations. |
| 2. To find any Code of Federal Regulations (C.F.R.) visit: www.access.gpo.gov. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 17-18-075, § 296-842-20010, filed 9/5/17, effective 10/6/17. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW. WSR 12-24-071, § 296-842-20010, filed 12/4/12, effective 1/4/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 07-05-072, § 296-842-20010, filed 2/20/07, effective 4/1/07; WSR 03-20-114, § 296-842-20010, filed 10/1/03, effective 1/1/04.]