Wash. Admin. Code § 296-826-30005
(1) You must locate containers either:
(2) You must locate containers according to Table 1, Minimum Distances for Container Location.
Table 1
Minimum Distances for Container Location
| Minimum Distances (feet) from Container to: | ||||
| Nominal Capacity of Container | Line of Adjoining Property Which may be Built upon, Highways & Mainline of Railroad | Place of Public Assembly | InstitutionOccupancy | |
| Over 500 to 2,000 | 25 | 150 | 250 | |
| Over 2,000 to 30,000 | 50 | 300 | 500 | |
| Over 30,000 to 100,000 | 50 | 450 | 750 | |
| Over 100,000 | 50 | 600 | 1,000 |
(3) You must make sure containers are located to meet all of the following:
(c) At least fifty feet away from dug wells and other sources of potable water.
| EXCEPTION: | If the container is a part of a water treatment installation, this requirement does not apply. |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-826-30005, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 06-10-067, § 296-826-30005, filed 5/2/06, effective 9/1/06.]