Wash. Admin. Code § 296-823-18055
(2) You must use two sets of doors to separate HIV and HBV work areas from access corridors or other contiguous areas.
| Note: | You may provide a physical separation of the high-containment work area from access corridors or other areas or activities by providing: |
| 1. A double-doored clothes-change room (showers may be included); | |
| 2. Airlock; or | |
| 3. Other access facilities that require passing through two sets of doors before entering the work area. |
(5) You must provide a ducted exhaust-air ventilation system.
(b) The exhaust air must:
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050. WSR 15-23-086, § 296-823-18055, filed 11/17/15, effective 12/18/15. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 07-03-163, § 296-823-18055, filed 1/24/07, effective 4/1/07; WSR 04-12-070, § 296-823-18055, filed 6/1/04, effective 9/1/04; WSR 03-09-110, § 296-823-18055, filed 4/22/03, effective 8/1/03.]