Wash. Admin. Code § 296-56-60145
(1) Employers must fully enclose elevator cars to car height or to a height of not less than six feet six inches whichever is greater. Elevator cars may be of perforated or solid material provided the material will withstand a horizontal thrust of 75 pounds without deflecting one-quarter inch and all openings will reject a one inch ball.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060, 70.54.480, and chapter 49.17 RCW. WSR 26-07-053, s 296-56-60145, filed 3/17/26, effective 4/20/26. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-56-60145, filed 12/1/15, effective 1/5/16. Statutory Authority: RCW 49.17.040 and 49.17.050. WSR 86-03-064 (Order 86-02), § 296-56-60145, filed 1/17/86; WSR 85-01-022 (Order 84-24), § 296-56-60145, filed 12/11/84.]