- (1) Motor logging trucks and trailers must be equipped with brakes or other control methods that will safely stop and hold the maximum load on the maximum grade.
- (2) All trucks with air brakes must be equipped with a readily visual or audible low air pressure warning device in good working order.
(3) An air loss rate out-of-service condition exists if an air leak is discovered and the reservoir pressure is not maintained when:
- (a) The governor is cut in;
- (b) Reservoir pressure is between 80 and 90 psi;
- (c) Engine is at idle; and
- (d) Service brakes are fully applied.
[Statutory Authority: RCW 49.17.010, [49.17].040 and [49.17].050. WSR 99-17-117, § 296-54-58910, filed 8/18/99, effective 12/1/99.]