Wash. Admin. Code § 296-54-567
(4) Extensions to skylines must be equal in breaking strength to the skyline to which they are attached and must not alter the safe capacity of the tower. In addition, the extension must be attached only by a regular long splice or by a flush pin straight side shackle connecting the two eyes.
| Note: | See exception in WAC 296-54-553 (4)(e). |
(5) Live, running or standing skylines must be anchored by one of the following methods:
(b) Directly to the base of a standing tree provided the point of attachment is no more than three feet above the ground and no part of the tree will enter the work area if pulled over;
(6) Skylines or mainlines must be secured by one of the following methods:
(7) Attaching the end of the skyline or slackline to the base of the rigged tail/lift tree is prohibited.
SKYLINE POSITIONING LIMITS TAIL/LIFT TREE
| [if IE 9]><video style="display: none;"><![endif][if IE 9]></video><![endif] |
| Figure 23: Skyline Positioning Limits Tail/Lift Tree |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060, and chapter 49.17 RCW. WSR 17-17-131, § 296-54-567, filed 8/22/17, effective 10/22/17. Statutory Authority: RCW 49.17.010, [49.17].040 and [49.17].050. WSR 99-17-117, § 296-54-567, filed 8/18/99, effective 12/1/99. Statutory Authority: RCW 49.17.040, [49.17].050 and [49.17].060. WSR 96-22-013, § 296-54-567, filed 10/28/96, effective 1/1/97. Statutory Authority: RCW 49.17.040 and 49.17.050. WSR 81-05-013 (Order 81-3), § 296-54-567, filed 2/10/81. Statutory Authority: RCW 49.17.040, 49.17.150 and 49.17.240. WSR 79-10-081 (Order 79-14), § 296-54-567, filed 9/21/79.]