Wash. Admin. Code § 296-52-69125
(1) Use Table H-24 for magazines that are restricted to:
(2) Detonators cannot be stored with low explosives.
Table H-24
TABLE OF DISTANCES FOR STORAGE OF LOW EXPLOSIVES
| Pounds | Frominhabited buildingdistance(feet) | Frompublicrailroad and highwaydistance (feet) | From above groundmagazine(feet) | |
| Over | Not Over | |||
| 0 | 1,000 | 75 | 75 | 50 |
| 1,000 | 5,000 | 115 | 115 | 75 |
| 5,000 | 10,000 | 150 | 150 | 100 |
| 10,000 | 20,000 | 190 | 190 | 125 |
| 20,000 | 30,000 | 215 | 215 | 145 |
| 30,000 | 40,000 | 235 | 235 | 155 |
| 40,000 | 50,000 | 250 | 250 | 165 |
| 50,000 | 60,000 | 260 | 260 | 175 |
| 60,000 | 70,000 | 270 | 270 | 185 |
| 70,000 | 80,000 | 280 | 280 | 190 |
| 80,000 | 90,000 | 295 | 295 | 195 |
| 90,000 | 100,000 | 300 | 300 | 200 |
| 100,000 | 200,000 | 375 | 375 | 250 |
| 200,000 | 300,000 | 450 | 450 | 300 |
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 17-16-132, § 296-52-69125, filed 8/1/17, effective 9/1/17; WSR 03-06-073, § 296-52-69125, filed 3/4/03, effective 8/1/03. Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. WSR 02-03-125, § 296-52-69125, filed 1/23/02, effective 3/1/02.]