- (1) When more than one charge is placed underwater, a float device must be attached to an element of each charge to make sure it will be released when the charge is fired.
- (2) Blasting flags must be displayed.
- (3) Misfires must be handled according to the requirements of WAC 296-52-67110(3), Misfires.
[Statutory Authority: RCW 49.17.010, [49.17].040, and [49.17].050. WSR 02-03-125, § 296-52-67200, filed 1/23/02, effective 3/1/02.]