(1) Gin pole use must comply with the following:
- (a) A user's gin pole load chart must be provided for each pole.
- (b) Any special engineered lift that is outside of the load chart must only be allowed at the direction of a registered professional engineer. Monitoring and measuring conditions, as specified by a registered professional engineer, must be provided and used during all special engineered lifts.
- (c) Modifications or repairs to the gin pole must be designed and approved by a professional engineer or a qualified gin pole design professional and the repairs inspected by a qualified person prior to returning to service.
- (d) A mechanism must be in place to prevent the gin pole from tipping during the jumping process.
(2) Wire rope used for rigging must be as follows:
- (a) Compatible with the sheaves of the rooster head and hoisting blocks.
- (b) Lubricated in accordance to manufacturer specifications to prevent corrosion and wear.
- (c) End connections must be terminated per industry and manufacturer's specifications.
- (d) Wedge sockets must have a minimum tail length of one rope lay with a properly torqued clip attached to prevent accidental disengagement.
- (e) Only manufactured Flemish eyes will be acceptable.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 20-20-109, § 296-32-24024, filed 10/6/20, effective 11/6/20. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060, and chapter 49.17 RCW. WSR 17-20-069, § 296-32-24024, filed 10/2/17, effective 1/1/18.]