Wash. Admin. Code § 296-150C-1070
Floor closure material
Effective Sep 30, 2000WSR 00-17-148RCW 43.22.340, 43.22.350, 43.22.355, 43.22.360, 43.22.400, 43.22.432, 43.22.433, 43.22.434, 43.22.450, 43.22.480, and 43.22.485LABOR AND INDUSTRIES, DEPARTMENT OF
The closure material must meet ASTM D-781 standard or equal and be installed as follows:
- (1) Fibrous material (with or without patches) must meet or exceed the level of 48 inch-pounds of puncture resistance as tested.
- (2) The material must be installed according to installation instructions furnished by the supplier of the material.
- (3) Patching material must be suitable for patches and the patch life must be equivalent to the material life.
- (4) Floor closure material around piping, ducts, plenums, or vents must prevent damage to the underside of the commercial coach due to air, water, insects, dust, and must be rodent resistant.
[Statutory Authority: RCW 43.22.340, 43.22.350, 43.22.355, 43.22.360, 43.22.400, 43.22.432, 43.22.433, 43.22.434, 43.22.450, 43.22.480, and 43.22.485. WSR 00-17-148, § 296-150C-1070, filed 8/22/00, effective 9/30/00. Statutory Authority: RCW 43.22.340, [43.22.]355, [43.22.]360, [43.22.]432, [43.22.]440 and [43.22.]480. WSR 96-21-146, § 296-150C-1070, filed 10/23/96, effective 11/25/96.]