Wash. Admin. Code § 246-366-120
(1) The following maintained light intensities shall be provided as measured 30 inches above the floor or on working or teaching surfaces. General, task and/or natural lighting may be used to maintain the minimum lighting intensities.
| Minimum Foot - Candle Intensity | |
| General instructional areas including: Study halls, lecture rooms and libraries. | 30 |
| Special instructional areas where safety is of prime consideration or fine detail work is done including: Sewing rooms, laboratories (includes chemical storage areas), shops, drafting rooms and art and craft rooms. | 50 |
| Kitchen areas including: Food storage and preparation rooms. | 30 |
| Noninstructional areas including: Auditoriums, lunch rooms, assembly rooms, corridors, stairs, storerooms, and toilet rooms. | 10 |
| Gymnasiums: Main and auxiliary spaces, shower rooms and locker rooms. | 20 |
[Statutory Authority: RCW 43.20.050. WSR 91-02-051 (Order 124B), recodified as § 246-366-120, filed 12/27/90, effective 1/31/91; WSR 82-07-015 (Order 225), § 248-64-330, filed 3/9/82; Order 124, § 248-64-330, filed 3/18/76; Order 55, § 248-64-330, filed 6/8/71.]