TWH habitable structures:
- (1) Must have a primary entrance, which is at a minimum, three foot-by-six foot eight-inch exit door made of solid core wood or other material designed for use as an exterior door.
- (2) Must have at least two exit doors when accommodating ten or more occupants. When two exit doors are required, the doors must be placed a distance apart equal to at least one-half of the length of the maximum overall diagonal dimension of the building area used.
- (3) Provide a locking mechanism on the exterior door(s) of each family shelter. The mechanism must not prevent egress, and must be easily opened from the inside without use of a key or special knowledge.
- (4) Provide a locking mechanism on all bedroom doors, excluding doors to common sleeping areas. The mechanism must not prevent egress and must be easily opened from the inside without use of a key or special knowledge.
- (5) Provide a locking mechanism on all bedroom doors, excluding doors to bedrooms housing more than fifteen occupants.
(6) Provide a locking mechanism on:
- (a) Each toilet stall door, if provided; and
- (b) Each shower stall door, if provided.
- (7) Must have all exterior door openings screened with sixteen-mesh material self-closing screen doors, including toilet facilities.
- (8) With a calculated occupant load of fifty occupants or more must have a screen door which swings in the direction of exiting.
- (9) With latched screen doors must have a roller type latch.
[Statutory Authority: Chapter 70.114A RCW and RCW 43.70.334 through 43.70.340. WSR 15-13-091, § 246-359-510, filed 6/15/15, effective 1/1/16. Statutory Authority: RCW 70.114A.081. WSR 99-03-065, § 246-359-510, filed 1/18/99, effective 2/18/99.]